Detection Advanced - Optex REDSCAN mini-Pro Series Settings Manual

Laser scan detector
Hide thumbs Also See for REDSCAN mini-Pro Series:
Table of Contents

Advertisement

RLS-2020V 1.x.x (xxxx/xx/xx)
Apply settings
Detection range
Detection profile 1
Detection area
Area Masking/Allocating
Detection

Detection advanced

Output termina
Detection profile copy
Detection profile 2
Event code
View
Date and Time
Network
Maintenance
Information
Save
Detection advanced
Environmental resistance Enable
Auto area adjustment
Adjust detection area
Adjust boundary area
Excluded distance from
the detector (m)
Alarm duration
Mode
Continue
Specified time (sec.)
Boundary Recognition
Accuracy
Normal
Anti-masking
Use anti-masking
Judgement time (sec.)
60
Area ratio (%)
10
Sensitivity
Low
Anti-rotating
Use anti-rotating
Judgement time (sec.)
300
Sensitivity
Low
Soiling of laser window
Use soiling of laser window
Judgement time (sec.)
300
Area ratio (%)
40
DQ output
Use DQ output
Off delay time (sec.)
120
?
4-2-4. Detection advanced
1. Common items for Horizontal/Vertical mode
Environmental resistance
[ Disable, Enable, Enhanced ]
Disable: Response time of alarm is minimum but false alarm can
increase in harsh environment such as fog or snow.
Enable: False alarm can be reduced by balanced detection ability.
Enhanced: False alarm due to fog or snow is reduced, but
response time is longer and some objects may not be detected.
Auto area adjustment
REDSCAN mini-Pro continues to learn background area and update
background information gradually. By checking Adjust Detection
Area, the detection area is adjusted proportionally to the
background. (i.e. False alarm by snow can be reduced.)
Adjust detection area
When enabled, adjusts the detection area. To adjust the detection
area, Adjust boundary area must be enabled.
Adjust boundary area
When enabled, adjusts the boundary area.
5
Boundary Recognition Accuracy
By changing this parameter that defines the accuracy for the
recognition of the boundary (e.g. wall, floor, ground), the unit
may easily detect the target which is located near the boundary.
0
Default value is Normal. "High" can be selected.
Higher accuracy condition, the unit can detect the target near
the boundary, on the other hand, there is a possibility that it
makes false alarms by noise from the surface.
Therefore it is advised to carry out a test to check its affect
carefully at the actual site before operation .
Anti-masking enable
Judgement time (sec.)
Area ratio (%)
Sensitivity
Anti-rotating enable
Judgement time (sec.)
Sensitivity
Soiling of laser window enable
Judgement time (sec.)
Area ratio (%)
DQ (Disqualify) output enable
Off-delay timer (sec.)
Anti-Masking
Detects obstacles which mask the detector.
Anti-Rotation
Detects if the unit is rotated.
Soiling of the Window
Detects dirt is soiling detector window.
DQ (Environmental Disqualification) output
Detects harsh environment, fog, rain, or snow for example.
23
Outdoor mode
[ Low, Normal, High ]
[ 1 to 600
(= 10 min.)
[ 10 to 100 ]
[ Low, Middle, High ]
[ 1 to 600
(= 10 min.)
[ Low, Middle, High ]
[ 1 to 600
(= 10 min.)
[ 10 to 100 ]
[ 1 to 600
(= 10 min.)
4. Settings