Optex REDSCAN mini-Pro Series Settings Manual page 24

Laser scan detector
Hide thumbs Also See for REDSCAN mini-Pro Series:
Table of Contents

Advertisement

RLS-2020V 1.x.x (xxxx/xx/xx)
Apply settings
Detection range
Detection profile 1
Detection area
Area Masking/Allocating
Detection
Detection advanced
Output terminal
Detection profile copy
Detection profile 2
Event code
View
Date and Time
Network
Maintenance
Information
RLS-2020V 1.x.x (xxxx/xx/xx)
Apply settings
Detection range
Detection profile 1
Detection area
Area Masking/Allocating
Detection
Detection advanced
Output terminal
Detection profile copy
Detection profile 2
Event code
View
Date and Time
Network
Maintenance
Information
Save
Detection advanced
Environmental resistance Enable
Auto area adjustment
Adjust detection area
Adjust boundary area
Excluded distance from
the detector (m)
Alarm duration
Mode
Continuous
Specified time (sec.)
Save
Detection advanced
Non-detection zone (m)
1.5
Environmental resistance Enable
Auto area adjustment
Adjust detection area
Adjust boundary area
Maximum adjusting
height (m)
1
Small animal tolerance
?
2. Horizontal mode
Excluded distance from the detector (m)
[ 0 to 20 rectangle, 0 to 30 fanshape]
In horizontal mode, it follows background changes excluding
closer area to the detector than the parameter value, and
updates the detection area appropriately.
5
Alarm duration
Mode
[ Continuous, Preset ]
Continuous:
As long as an object remains in the detection area after
0
detection, it keeps the alarm condition.
Preset:
Even though an object remains in the detection area after
detection, the alarm will be restored after the preset time.
?
Specified time (sec.)
Setting for alarm duration after detection.
3. Vertical mode
Non-detection zone (m)
[ 0 to 20 rectangle, 0 to 30 fanshape]
Objects near to ceiling are ignored.
In vertical detection area, protruding objects on the ceiling can
cause false alarm. Enter the height of the ignoring area.
Maximum adjusting height (m)
[ 0 to 20 rectangle, 0 to 30 fanshape]
In vertical mode, the auto area adjustment can be limited using
this setting. Changes under the height are learned as background.
Small animal tolerance
In vertical mode, small animals on the ground are ignored by this
function.
24
Mobile object
only
[ 1 to 30,000
( = 500 min.)