Advertisement

REDSCAN Manager Advanced Help
Version 8.3.3.0
REDSCAN Manager Advanced is Windows application software to configure REDSCAN series, RLS-2020I,
RLS-2020S, RLS-3060L, and RLS-3060SH.
Once RLS-3060SH/L were adjusted with REDSCAN Manager Ver.8 or later, do not readjusted with its
earlier than Ver.8 in order to avoid unexpected activations.

Advertisement

Table of Contents
loading

Summary of Contents for Optex REDSCAN Series

  • Page 1 REDSCAN Manager Advanced Help Version 8.3.3.0 REDSCAN Manager Advanced is Windows application software to configure REDSCAN series, RLS-2020I, RLS-2020S, RLS-3060L, and RLS-3060SH. Once RLS-3060SH/L were adjusted with REDSCAN Manager Ver.8 or later, do not readjusted with its earlier than Ver.8 in order to avoid unexpected activations.
  • Page 2: Table Of Contents

    Contents REDSCAN Manager Quick Start ........................4 [Install of REDSCAN Manager] ........................4 [PC Settings for REDSCAN Manager]......................5 [Connecting to REDSCAN] ........................... 7 [Area Set] ..............................10 [REDWALL Event Code Settings] ....................... 13 [Terminal Settings] ............................15 [Disconnecting REDSCAN]......................... 19 [Recommended PC Specifications] ......................
  • Page 3 [Area Masking] RLS-2020 series, RLS-3060SH or RLS-3060L (version 8.0.0 or later)......64 [Area Allocating] RLS-2020 series, RLS-3060SH or RLS-3060L (version 8.0.0 or later)......66 [REDWALL Event Code Settings] ....................... 68 [Terminal Settings] ............................70 [Network Settings] ............................74 [Detector Authentication]..........................
  • Page 4: Redscan Manager Quick Start

    REDSCAN Manager Quick Start This Quick Start shows minimum sequence to set up REDSCAN series. [Install of REDSCAN Manager] 1. Download the latest version of REDSCAN Manager Advanced installer from the web page. http://www.optex.co.jp/e/redwall/download/index.html 2. Start the installer. 3. Follow the instructions.
  • Page 5: [Pc Settings For Redscan Manager]

    [PC Settings for REDSCAN Manager] REDSCAN mini has 2 LAN ports, main and maintenance. Default settings of main Ethernet Port: ⚫ IP Address 192.168.0.126 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.1 ⚫ Default settings of Maintenance Port: IP Address 192.168.1.126 Subnet Mask 255.255.255.0 1.
  • Page 6 (3) Select Inbound Rules, then select REDSCAN Manager Advanced from the list. (4) Double-click on REDSCAN Manager Advanced to open Properties. (5) On the General tab, select Allow Connect and click OK. On the Advanced settings tab, check all profiles. If there are multiple REDSCAN Manager Advanced in the list, change settings of the all REDSCAN Manager Advanced.
  • Page 7: [Connecting To Redscan]

    RLS-2020 series: User ID and Password can be changed. Default User ID: REDSCAN Default Password: OPTEX Once the connection between REDSCAN Manager Advanced software and the REDSCAN unit was established, the authentication information was stored. But, if they were changed by WEB browser or other REDSCAN Manager software, entering user ID and...
  • Page 8 1. Start REDSCAN Manager. 2. Enter User ID and Password. Default settings are REDSCAN and OPTEX. If Windows Firewall Message appears, check all 3 boxes and allow the access. 3. If REDSCAN Manager is started for the first time, Initial Settings are required.
  • Page 9 4. Click Connect button at upper left. If Windows Firewall Message appears, check all 3 boxes and allow the access. Click connect button again.
  • Page 10: [Area Set]

    [Area Set] Area Set enables to learn background of the area. The background information is base for decreasing false alarm. [RLS-2020] 1. If Area Set is not done yet, the 2nd button is active. Click the Area Set button. 2. Dialog box will appear. Click OK. Area Set will be completed in 15 seconds. 3.
  • Page 11 [RLS-3060] 1. If Area Set is not done yet, the 2nd button is active. Click the Area Set button. 2. Dialog box will appear. Click P1 Auto Learning or P2 Auto Tracing. 3. P1 Auto Learning will be completed in 20 seconds. In caase of P2 Auto Tracing, walking along the boundary of the area within 300 seconds.
  • Page 12 It is recommended to confirm the detection area by walk-test. To adjust the detection area, refer the page below. [Adjusting Detection Area] For detailed settings, refer pages below. [Detection Mode: Basic Settings] (RLS-2020 series) [Detection Mode: Advanced Settings] (RLS-2020 series) [Detection Mode: Basic Settings] (RLS-3060SH) [Detection Mode: Advanced Settings] (RLS-3060SH) [Detection Mode: Basic Settings] (RLS-3060L)
  • Page 13: [Redwall Event Code Settings]

    [REDWALL Event Code Settings] Configure REDWALL Event Code (R.E.C.) settings. R.E.C. is stored in UDP or TCP payload and sent from REDSCAN as alarm. Refer INSTALLTION INSTRUCTIONS or REDWALL Event Code specifications for details of the code. If you do not use R.E.C., skip this page. Click I/O Settings button (the 4th button).
  • Page 14 Notes: ⚫ To show R.E.C. on REDSCAN Manager, UDP is required. Select Broadcast, or Unicast with IP Address of the PC. ⚫ To send R.E.C. to VMS (Video Management Software), TCP is recommended. Select TCP and set IP Address of the PC of VMS. ⚫...
  • Page 15: [Terminal Settings]

    [Terminal Settings] Select relay output settings. If you do not use relay output, skip this page. Click I/O Settings button (the 4th button). Dialog box will appear. Click Terminal tab. RLS-2020 Terminal tab screen (Versions earlier than 2.1.0)
  • Page 16 RLS-2020 Terminal tab screen (Version 2.1.0 or later) Signal Output 1 - 3 Select NC (Normally Closed) or NO (Normally Open). Note: When power is down, signal outputs are opened. Assign A1 - DM to Output 1 -3. Default settings are: ⚫...
  • Page 17 Select preferable Action triggered by signal input. ⚫ Signal Output N for confirmation of the function: Signal Output N is activated. ⚫ Switching to Next Masking / Allocating File: Current Masking/Allocating Files is switched to next File. ⚫ Area Set: Area Set is started. Response is available when Switching to Next Masking / Allocating File or Area Set is selected.
  • Page 18 Meanings of abbreviations ⚫ N.C.: Normally Closed N.O.: Normally Open ⚫ ⚫ A1: A1 area set by Allocating function ⚫ A2: A2 area set by Allocating function ⚫ B1: B1 area set by Allocating function ⚫ B2: B2 area set by Allocating function ⚫...
  • Page 19: [Disconnecting Redscan]

    [Disconnecting REDSCAN] After settings and confirmation by walk-test, disconnect REDSCAN. Click Disconnect button (the 5th button). Close REDSCAN Manager.
  • Page 20: [Recommended Pc Specifications]

    [Recommended PC Specifications] Operating System Microsoft Windows 7 Professional (32 bit) Microsoft Windows 7 Professional (64 bit) Microsoft Windows 8.1 Professional (32 bit) Microsoft Windows 8.1 Professional (64 bit) Microsoft Windows 10 Professional (32 bit) Microsoft Windows 10 Professional (64 bit) Intel®...
  • Page 21: Redscan Manager Trouble Shooting

    REDSCAN Manager Trouble Shooting Can not Install REDSCAN Manager Install to recommended PC below. [Recommended PC Specifications] If REDSCAN Manager is running, close the REDSCAN Manager. If another installer is running, wait for the install to complete. Can not connect to REDSCAN RLS-2020 series has 2 LAN ports, main Ethernet port and Maintenance port.
  • Page 22: Can Not Set/Save Settings To Redscan

    Click Edit Detector Information button of REDSCAN Manager. Is the IP Address of the target REDSCAN registered? Is correct model name selected? [Group Registration] Note: Capturing packets by WireShark enables detailed investigation. Check the detector authentication. [When the authentication screen is displayed.] [Forget detector authentication.] Can not set/save settings to REDSCAN.
  • Page 23: Redwall Event Code Does Not Work On Milestone Xprotect

    REDWALL Event Code does not work on Milestone XProtect. Check R.E.C. settings. Is the destination IP address of R.E.C. correct? Check Windows firewall settings of the XProtect PC. Is the destination port number allowed? Is the XProtect waiting for the destination port number of R.E.C? [REDWALL Event Code Settings] To add multiple REDSCANs to Milestone XProtect, destination port numbers should be different each other.
  • Page 24: Redscan Manager Function List

    REDSCAN Manager Function List [Install of REDSCAN Manager] Download the latest version of REDSCAN Manager Advanced installer from the web page. http://www.optex.co.jp/e/redwall/download/index.html Start the installer. Follow the instructions. [Recommended PC Specifications]...
  • Page 25: [Pc Settings For Redscan Manager]

    [PC Settings for REDSCAN Manager] REDSCAN mini has 2 LAN ports, main and maintenance. Default settings of main Ethernet Port: ⚫ IP Address 192.168.0.126 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.1 ⚫ Default settings of Maintenance Port: IP Address 192.168.1.126 Subnet Mask 255.255.255.0 Change network settings of the PC to communicate with REDSCAN.
  • Page 26 (3) Select Inbound Rules, then select REDSCAN Manager Advanced from the list. (4) Double-click on REDSCAN Manager Advanced to open Properties. (5) On the General tab, select Allow Connect and click OK. On the Advanced settings tab, check all profiles. If there are multiple REDSCAN Manager Advanced in the list, change settings of the all REDSCAN Manager Advanced.
  • Page 27: [Login]

    [Login] Start REDSCAN Manager. Enter User ID and Password. Default settings are REDSCAN and OPTEX. To change Login password, click Change Password button. If you want to skip the Login from next time, check the checkbox. The PC remembers the password.
  • Page 28: [Group Registration]

    [Group Registration] Group 1 is default group in which default unit Detector 1 is registered. To edit registered group or detector information, disconnect current detector. To change registered information of Detector 1, click Edit Detector Information button. Enter preferable name, select target model, and enter IP address of the target REDSCAN. To show R.E.C.
  • Page 29 Click Add Detector button. Enter Name, select model name, and enter IP address of target unit. To change the settings, select the detector in the list, and click Edit Detector button. To delete a detector, select the detector in the list, and click Delete Detector button. To register new group, click Edit Group/Detector Information button.
  • Page 30 Enter group name and click Add button. To delete a group, click Edit Group button, select the group in the list, and click Delete button. To Export/Import Group Information Click Edit Group/Detector Information button. [Export] Select a group in the group list. Click Export button and save a xml file.
  • Page 31: [Connecting To Redscan]

    RLS-2020 series: User ID and Password can be changed. Default User ID: REDSCAN Default Password: OPTEX Once the connection between REDSCAN Manager Advanced software and the REDSCAN unit was established, the authentication information was stored. But, if they were changed by WEB browser or other REDSCAN Manager software, entering user ID and...
  • Page 32 Click Connect button at upper left. If Windows Firewall Message appears, check all 3 boxes and allow the access. Click Connect button again. Information of the REDSCAN will be displayed in Properties window.
  • Page 33 Properties window can be closed by close button. To show the window again, see the page below. REDSCAN Manager Settings When the REDSCAN sends REDWALL Event Code (R.E.C.), it will be displayed under the map. When some object is detected in A1,A2,B1,B2, A1,A2,B1,B2 lamp shows it. Masking Allocating file can be switched by selecting a file and click Replace button.
  • Page 34: [Area Set]

    [Area Set] Area Set enables to learn background of the area. The background information is base for decreasing false alarm. [RLS-2020] 1. If Area Set is not done yet, the 2nd button is active. Click the Area Set button. 2. Dialog box will appear. Click OK. Area Set will be completed in 15 seconds. 3.
  • Page 35 [RLS-3060] 1. If Area Set is not done yet, the 2nd button is active. Click the Area Set button. 2. Dialog box will appear. Click P1 Auto Learning or P2 Auto Tracing. 3. P1 Auto Learning will be completed in 20 seconds. In caase of P2 Auto Tracing, walking along the boundary of the area within 300 seconds.
  • Page 36 It is recommended to confirm the detection area by walk-test. To adjust the detection area, refer the page below. [Adjusting Detection Area] For detailed settings, refer pages below. [Detection Mode: Basic Settings] (RLS-2020 series) [Detection Mode: Advanced Settings] (RLS-2020 series) [Detection Mode: Basic Settings] (RLS-3060SH) [Detection Mode: Advanced Settings] (RLS-3060SH) [Detection Mode: Basic Settings] (RLS-3060L)
  • Page 38: [Detection Mode: Basic Settings] (Rls-2020 Series)

    [Detection Mode: Basic Settings] (RLS-2020 series) Click Settings button (the 3rd button). Dialog box will appear. Select preferable settings. To set default settings, click Restore default settings button.
  • Page 39 [Detection Mode] (Default: Indoor Mode) ⚫ Indoor Mode: For general indoor applications. Can make vertical detection area or horizontal detection area according to the mounting direction. ⚫ Indoor High Resolution Mode (RLS-2020S Only): By increasing detection resolution, the unit can detect small object at longer distance.
  • Page 40: [Detection Mode: Advanced Settings] (Rls-2020 Series)

    [Detection Mode: Advanced Settings] (RLS-2020 series) Click Setting button (the 3rd button). Dialog box will appear. Click Show Advanced Settings. Select preferable settings. [Detection Area] ⚫ Vertical: Creating a detection area perpendicular to the ground, such as wall protection. ⚫ Horizontal: Creating a detection area in parallel with the ground, such as ceiling protection.
  • Page 41 [Environmental Resistance] (Outdoor mode Only) ⚫ Disable: Select it for applications to control PTZ camera. Response time of alarm is minimum but false alarm can increase in harsh environment such as a fog or snow. ⚫ Enable: False alarm can be reduced by balanced detection ability. ⚫...
  • Page 42 [Small Animal Tolerance] (Vertical mode Only) In vertical mode, small animals on the ground are ignored by this function. [Anti-Masking] This is to detect obstacles which mask the detector. The result is reflected to relay output and R.E.C. ⚫ Judgement Time: Set the minimum duration for the detection. Area Ratio: Set the minimum ratio of masked area for the detection.
  • Page 43 [DQ Output] (RLS-2020S Only) If it is enabled, DQ Output is activated while fog, rain, or snow is detected. DQ Output can be included in relay output and R.E.C. ⚫ Off Delay Time: Set the time to deactivate the DQ Output after the detection of fog, rain, or snow is finished.
  • Page 44: [Detection Mode: Basic Settings] (Rls-3060Sh)

    [Detection Mode: Basic Settings] (RLS-3060SH) Click Settings button (the 3rd button). Dialog box will appear. Select preferable settings.
  • Page 45 [Detection Mode] (Default: Outdoor mode) ⚫ Outdoor mode This option is for general outdoor applications. As required, select the Vertical or Horizontal setting, and then set any additional settings. ⚫ Outdoor Fence/Wall top protection mode Select this mode if you want to detect a person trying to climb over a fence with the REDSCAN unit installed in a general outdoor environment.
  • Page 46 [Detection Area] (Default: H2) There are 3 options, Horizontal Detection Area 1, Horizontal Detection Area 2 and Vertical Detection Area. H1 (Horizontal Detection Area 1) ⚫ This mode allows setting of a fan-like detection area in the horizontal direction with a maximum radius of 30 m (Approx.100 ft.), a spread angle of 180 degrees, and a width of 1 m (variable).
  • Page 47 This mode will detect an object that traverses the detection area. [Sensitivity] (Default: Middle) The Sensitivity is to avoid false alarm caused by instantaneous event. If an object is detected longer than the Sensitivity time, alarm is issued. [Minimum Target Size (Width)] (Default: Middle) The Size is to avoid false alarm caused by small object.
  • Page 48: [Detection Mode: Advanced Settings] (Rls-3060Sh)

    [Detection Mode: Advanced Settings] (RLS-3060SH) Click Setting button (the 3rd button). Dialog box will appear. Click Show Advanced Settings. Select preferable settings. [Environmental Resistance] This function is to reduce false alarms in harsh environments, e.g. fog, snow, etc., can work in Outdoor Fence / Wall top protection and Outdoor Loitering detection.
  • Page 49 [Auto Area Adjustment] By enabling it, REDSCAN continues to learn background area and update background information gradually. In horizontal mode, learning area can be limited to Width of learning Perimeter. Changes in the perimeter are learned as background. In vertical mode, learning area can be limited to Maximum Adjusting Height. Changes under the height are learned as background.
  • Page 50 [Anti-Masking] This is to detect obstacles which mask the detector. The result is reflected to relay output and R.E.C. Judgement Time: Set the minimum duration for the detection. ⚫ ⚫ Area Ratio: Set the minimum ratio of masked area for the detection. ⚫...
  • Page 51 [DQ Output] If it is enabled, DQ Output is activated while fog, rain, or snow is detected. DQ Output can be included in relay output and R.E.C. ⚫ Off Delay Time: Set the time to deactivate the DQ Output after the detection of fog, rain, or snow is finished.
  • Page 52: [Detection Mode: Basic Settings] (Rls-3060L)

    [Detection Mode: Basic Settings] (RLS-3060L) Click Settings button (the 3rd button). Dialog box will appear. Select preferable settings.
  • Page 53 [Detection Mode] (Default: Outdoor mode) ⚫ Outdoor mode This option is for general outdoor applications. As required, select the Vertical or Horizontal setting, and then set any additional settings. ⚫ Outdoor Fence/Wall top protection mode Select this mode if you want to detect a person trying to climb over a fence with the REDSCAN unit installed in a general outdoor environment.
  • Page 54 ⚫ Vertical (Vertical Detection Area) This mode allows setting of a fan-like detection area in the vertical direction with a maximum radius of 30 m (Approx. 100 ft.), a spread angle of 180 degrees. This mode creates a non detection area, 1.5 m (variable) immediately in front of the unit, in order to avoid possible false alarms caused by birds or obstructions close to the unit.
  • Page 55: [Detection Mode: Advanced Settings] (Rls-3060L)

    [Detection Mode: Advanced Settings] (RLS-3060L) Click Setting button (the 3rd button). Dialog box will appear. Click Show Advanced Settings. Select preferable settings. [Environmental Resistance] This function is to reduce false alarms in harsh environments, e.g. fog, snow, etc., can work in Outdoor Fence / Wall top protection and Outdoor Loitering detection.
  • Page 56 [Auto Area Adjustment] By enabling it, REDSCAN continues to learn background area and update background information gradually. In horizontal mode, learning area can be limited to Width of learning Perimeter. Changes in the perimeter are learned as background. In vertical mode, learning area can be limited to Maximum Adjusting Height. Changes under the height are learned as background.
  • Page 57 [Anti-Masking] This is to detect obstacles which mask the detector. The result is reflected to relay output and R.E.C. Judgement Time: Set the minimum duration for the detection. ⚫ ⚫ Area Ratio: Set the minimum ratio of masked area for the detection. ⚫...
  • Page 58: [Adjusting Detection Area]

    [Adjusting Detection Area] Click Setting button (the 3rd button). Dialog box will appear. Click Detection Area button.
  • Page 59 In case of RLS-3060SH and RLS-3060L Version 8.0.0 or later, Detection Area Pattern is available. Detection Area Pattern is predefined allocating area below. (Detection Area Pattern can be overridden by Area Allocating.) Adjust size and position of the map as you like. ⚫...
  • Page 60 Limit detection area by Detection Range. ⚫ In case of RLS-2020 series, Detection area can be limited vertically/horizontally by Detection Range 1 and 2. Yellow lines show the Range 1 and 2. ⚫ In case of RLS-3060 series, Detection area can be limited by the radius of A and B. Yellow lines and arc indicate the effective detection range.
  • Page 61 ⚫ Return to Saved Settings button enables to cancel the temporal adjustment. ⚫ Cover All Sensing Area button enables to expand detection area to all sensing area. Show Area Updating button enables to show current sensing situation. By showing area update, you ⚫...
  • Page 62 (4) Adjust by adding and moving Box ⚫ Select Box adding tool and click a point on a line. Black box is added. Drag and drop the box. ⚫ ⚫ To delete a box, right click the box. Click Save button to save the change. [Detectable range based on a target size] RLS-2020 Indoor/Outdoor/Indoor throw-in mode Target size...
  • Page 63 RLS-2020 Indoor high-resolution mode Target size Black plate White plate 25 mm (1 in.) 4 m (14 ft.) 5 m (18 ft.) 50 mm (2 in.) 7 m (23 ft.) 9 m (29 ft.) 100 mm (4 in.) 13 m (41 ft.) 16 m (52 ft.) 150 mm (6 in.) 18 m (58 ft.)
  • Page 64: [Area Masking] Rls-2020 Series, Rls-3060Sh Or Rls-3060L (Version 8.0.0 Or Later)

    [Area Masking] RLS-2020 series, RLS-3060SH or RLS-3060L (version 8.0.0 or later). Click Setting button (the 3rd button). Dialog box will appear. Click Masking Allocating button. 3 files, No.2 to No.4, are supported by RLS-2020S and RLS-3060SH. To Mask Detection Area (1) Select File Number tab (RLS-2020S or RLS-3060SH).
  • Page 65 Save the changes. ⚫ Click Save button. Note: Block size of Area Masking / Allocating differs depending on model and setting. RLS-2020 series: 200 mm (0.66 ft.) RLS-3060 series: 300 mm (0.98 ft.) RLS-3060SH version 8.0.0 or later with detection range expansion: 500 mm (1.64 ft.)
  • Page 66: [Area Allocating] Rls-2020 Series, Rls-3060Sh Or Rls-3060L (Version 8.0.0 Or Later)

    [Area Allocating] RLS-2020 series, RLS-3060SH or RLS-3060L (version 8.0.0 or later). Click Setting button (the 3rd button). Dialog box will appear. Click Masking Allocating button. 3 files, No.2 to No.4, are supported by RLS-2020S and RLS-3060. Note: In default settings, all area is defined as A1. When an object is detected, A1 is reported by REDWALL Event Code and/or relay output.
  • Page 67 ⚫ If Disable is selected, the whole area becomes A1. ⚫ If Area Masking is selected, the whole area becomes A1. Save the changes. ⚫ Click Save button. Note: Block size of Area Masking / Allocating differs depending on model and setting. RLS-2020 series: 200 mm (0.66 ft.) RLS-3060 series: 300 mm (0.98 ft.) RLS-3060SH version 8.0.0 or later with detection range expansion: 500 mm (1.64 ft.)
  • Page 68: [Redwall Event Code Settings]

    [REDWALL Event Code Settings] Configure REDWALL Event Code (R.E.C.) settings. R.E.C. is stored in UDP or TCP payload and sent from REDSCAN as alarm. Refer INSTALLTION INSTRUCTIONS or REDWALL Event Code specifications for details of the code. If you do not use R.E.C., skip this page. Click I/O Settings button (the 4th button).
  • Page 69 Notes: ⚫ To show R.E.C. on REDSCAN Manager, UDP is required. Select Broadcast, or Unicast with IP Address of the PC. ⚫ To sent R.E.C. to VMS (Video Management Software), TCP is recommended. Select TCP and set IP Address of the PC of VMS. ⚫...
  • Page 70: [Terminal Settings]

    [Terminal Settings] Select relay output settings. If you do not use relay output, skip this page. Click I/O Settings button (the 4th button). Dialog box will appear. Click Terminal tab. RLS-2020 Terminal tab screen (Versions earlier than 2.1.0)
  • Page 71 RLS-2020 Terminal tab screen (Version 2.1.0 or later) Signal Output 1 - 3 Select NC (Normally Closed) or NO (Normally Open). Note: When power is down, signal outputs are opened. Assign A1 - DM to Output 1 -3. Default settings are: ⚫...
  • Page 72 Select preferable Action triggered by signal input. ⚫ Signal Output N for confirmation of the function: Signal Output N is activated. ⚫ Switching to Next Masking / Allocating File: Current Masking/Allocating Files is switched to next File. ⚫ Area Set: Area Set is started. Response is available when Switching to Next Masking / Allocating File or Area Set is selected.
  • Page 73 Meanings of abbreviations ⚫ N.C. : Normally Closed N.O. : Normally Open ⚫ ⚫ A1 : A1 area set by Allocating function ⚫ A2 : A2 area set by Allocating function ⚫ B1 : B1 area set by Allocating function ⚫...
  • Page 74: [Network Settings]

    [Network Settings] Select Advanced Settings and click Network button (the 7th button). Dialog box will appear. ⚫ Enter preferable settings. Caution: IP addresses of Main Port and Maintenance Port must be in different network segment. For example, to set 192.168.1.* to Main port, change IP address of Maintenance Port to another network segment.
  • Page 75: [Detector Authentication]

    [Detector Authentication] Select Advanced Settings and click Password button (the 8th button). Dialog box will appear. ⚫ Enter new User ID and Password. (Notes:RLS-3060: Password only) Save the changes. ⚫ Click OK button. Notes: Once the connection between REDSCAN Manager Advanced software and the REDSCAN unit was established, the authentication information was stored.
  • Page 76: [Export/Import]

    [Export/Import] Detector settings can be exported to xml file. Exported file can be imported by Import function. Select Advanced Settings and click Import/Export button (the 9th button). Dialog box will appear. Export To export settings, Click Export Setting button. Settings are exported to xml file. Import To import settings, select Detection Settings, Event Code and I/O Settings, and/or Network Settings.
  • Page 77 Detection Settings contains settings in pages below. I/O Settings contains settings in pages below. Network Settings contains settings in pages below.
  • Page 78: [Snapshot]

    [Snapshot] This function enables capturing current GUI image of REDSCAN Manager. Click Tools menu. Click Snapshot button. Captured image is shown in dialog box. Save. ⚫ Click Save button, and enter JPEG file name.
  • Page 79: [Recording]

    [Recording] This function enables recording GUI of REDSCAN Manager as moving picture. Click Tools menu. Click Record button. ⚫ Frame Rate: Select preferable frame rate. ⚫ Pre-alarm Recording Time: Select preferable time. ⚫ Post-alarm Recording Time: Select preferable time. Trigger of REDWALL Event Code: Select conditions to trigger recording. ⚫...
  • Page 80: [Playback]

    [Playback] This function enables to playback recorded file. Click Tools menu. Note: Playback is not available when REDSCAN is connected. Disconnect REDSCAN before playback. Click Playback button. ⚫ Folder: Select folder of recorded files. ⚫ File List: Recorded files in the folder are displayed. ⚫...
  • Page 81: [View]

    [View] The graphics of REDSCAN Manager can be customized. Click View menu. Select preferable settings. ⚫ Vertical Flip: Flips the map vertically. ⚫ Horizontal Flip: Flips the map horizontally. ⚫ Sensing Area: Shows the all sensing area. Except in the detection area, objects in sensing area are recognized but not detected, and no alarm is issued.
  • Page 82: [Redscan Manager Settings]

    [REDSCAN Manager Settings] Select REDSCAN Manager Settings menu. Click Option button. Login window can be enabled or disabled on Login tab. ⚫ If it is enabled, User ID and Password are requested when REDSCAN Manager is started. Icon size can be changed on Menu tab.
  • Page 83 Properties window can be enabled or disabled on Properties tab. Length of unit can be selected on Properties tab. Source port number used when communicating with REDSCAN can be changed on Communication tab. If 0 is specified, the source port number is automatically assigned. If PC performance is not enough for drawing graphics, select Low or Ultra Low on PC Performance tab.
  • Page 84: [Disconnecting Redscan]

    [Disconnecting REDSCAN] After settings and confirmation by walk-test, disconnect REDSCAN. Click Disconnect button (the 5th button). Close REDSCAN Manager.
  • Page 85: Redscan Manager Glossary

    REDSCAN Manager Glossary A1/A2/B1/B2 ⚫ RLS-2020 series: Name of allocated areas. In default settings, all area is defined as A1. ⚫ RLS-3060 series: Name of areas in fixed pattern, or name of allocated area. Colors showed on the Map Anti-Masking ⚫...
  • Page 86 Area Masking ⚫ Masking area is available to ignore some area and reduce false alarm. Area Set ⚫ Learns background of the area. Detection Mode ⚫ Selectable for customer's application. DQ (Environmental Disqualification) ⚫ Detects harsh environment, fog, rain, or snow for example. Environmental Resistance ⚫...
  • Page 87 ⚫ R.E.C. is stored in UDP or TCP packet and sent from REDSCAN as alarm. REDSCAN ⚫ Optex product that detects objects by laser scanning. There are 2 series, RLS-2020 series and RLS- 3060 series. REDSCAN Manager ⚫ Windows application software to configure REDSCAN.