Service Rules; Symbols - TOHATSU BFT 200D Rigging Manual

Hide thumbs Also See for BFT 200D:
Table of Contents

Advertisement

dummyhead
BF175D/BF200D/BF225D/BF250D

SERVICE RULES

• Use Honda-recommended lubricants or their equivalents.
• When torquing bolts or nuts, begin with larger-diameter or inner bolts first and tighten to the specified torque
diagonally, unless a particular sequence is specified.
• Lubricate any sliding surfaces before reassembly.
• After reassembly, check all parts for proper installation and operation.
• Metric bolts, nuts and screws are not interchangeable with non-metric fasteners. The use of incorrect tools and
fasteners will damage the unit.
• Hold the connector body to disconnect the connector. Do not disconnect by pulling the wire harness. To disconnect
the locking connector, be sure to unlock first, then disconnect.
• Check the connector terminals for excessive extrusion, missing terminals, bends, or other abnormalities before
connecting the connector.
• To connect, insert the connector as far as it goes. If the connector is a locking type, be sure that it is locked
securely.
• Check the connector cover for breakage and check whether the connector female terminal is not open excessively.
Then, connect the connector securely. Check the connector terminal for rust. Remove rust using emery paper or
equivalent material before connecting the connector.
• Set the harness clips in the specified places securely, and secure the wire harness.
• Clamp the cables securely.
• Clamp the wire harnesses securely so that they do not interfere with the rotating parts, moving parts and the hot
parts.
• Route and connect the wire harnesses properly. Be sure that the harnesses are not slack, twisted or pulled taut.
• Route the wire harnesses properly so that they do not contact sharp edges or corners, and the end of the bolts and
screws on the body.
• If a wire harness contacts the end of bolts/screws, sharp edges or corners, protect the contact part of the wire
harness with a tube or by winding with electrical insulating tape. If the wire harness has a grommet, set the
grommet securely.

SYMBOLS

The symbol used throughout this manual show specific service procedure.
4