Measure The Ac Voltage; Measure The Dc Voltage - ABB InCharge Terra 184 Manual

All-in-one 90kw dc fast charger
Hide thumbs Also See for InCharge Terra 184:
Table of Contents

Advertisement

Procedure
1. Set the upstream breaker which provide the power to this EVSE to OFF and lock
it. Make sure that this breaker stays in the OFF position during the procedure.
2. Open the front door and the right door. Refer to section 8.1.
3. Measure the AC voltage. Refer to section 6.6.2.
4. Make sure that all the measured voltages are 0 V.
5. Measure the DC voltage. Refer to section 6.6.3.
6. Make sure that all the measured voltages are 0 V.
7. Close the doors. Refer to section 8.2.
6.6.2

Measure the AC voltage

Preliminary requirements
Procedure
1. Measure the AC voltage between the terminals on the surge protection device
switch:
Use the voltage tester.
6.6.3

Measure the DC voltage

Preliminary requirements
9AKK108466A3703-EN | 001
Owner
Voltage tester. Refer to
section 10.5.
L1 to L2
L1 to L3
L2 to L3
Note: The surge protection device switch shows the indications L1, L2
and L3.
Owner
Voltage tester. Refer to
section 10.5.
Only do this procedure if a
different procedure refers
to this procedure.
Only do this procedure if a
different procedure refers
to this procedure.
Operation
61

Advertisement

Table of Contents
loading