Ac Input Specifications; General Specifications; Ac Input Specifications (Europe); Ac Input Specifications (North America, Terra Ac Wx-P8-Xxxxx) - ABB Terra AC User Manual

Hide thumbs Also See for Terra AC:
Table of Contents

Advertisement

Parameter
Z1
Z2 (indoor use)
Z2 (outdoor use)
7.7

AC input specifications

7.7.1

General specifications

Parameter
Earthing systems
Frequency
Overvoltage category
Protection
7.7.2

AC input specifications (Europe)

Parameter
Input AC power connection
Input voltage (1 phase)
Input voltage (3 phase)
Standby power consumption
Earth (ground) fault protection
Maximum input power (1 phase)
Maximum input power (3 phase)
7.7.3

AC input specifications (North America, Terra AC Wx-P8-xxxxx)

Parameter
Input AC power connection
Standby power consumption
Earth (ground) fault protection
1
Only for EVSEs in Europe
BCM.V3Y00.0-EN | 002 - DRAFT
Specification [mm]
> 200
450 to 1200
600 to 1200
Specification
TT
TN-S
TN-C-S
50 Hz or 60 Hz
Category III
Overcurrent
Overvoltage
Undervoltage
Earth fault, including DC leakage protec-
1
tion
Integrated surge protection
Specification
1 phase or 3 phase
220 to 240 VAC
380 to 415 VAC
4.6 W
30mA AC, 6 mA DC
3.7 kW (16 A)
7.4 kW (32 A)
11 kW (16 A)
22 kW (32 A)
0.25-5 (32) A for MID certified models
Specification
240 V AC
3.6 W
internal 20 mA AC CCID
Technical data
Specification [inches]
> 8
18 to 48
24 to 48
45

Advertisement

Table of Contents
loading

Table of Contents