Aerotech VascuLathe ACS Series User Manual page 49

Table of Contents

Advertisement

®
VascuLathe
-ACS Hardware Manual
Step 6: Lubricate the new seal with a generous amount of Parker O-Lube and press it uniformly into its hous-
ing.
Step 7: Apply Parker O-Lube to the exposed end of the rotary union shaft as shown in
Step 8: Press the seal assembly back over the rotary union shaft onto the housing. Use care so that damage
does not occur to the newly installed seal.
Step 9: Tighten the seal assembly screws and reattach covers.
Step 10: Restore power to the stage.
www.aerotech.com
Figure 4-12:
Wet Cut Rotary Union Shaft Inspection
Chapter 4
Maintenance
Figure
4-12.
41