Electrical Installation; Mounting Procedure - STEINEL LS 300 S Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
LS 300 S product components (Fig. 3.8)
A
LED panel
B
Enclosure
C
Wall mount
Technical specifications
– Dimensions (H × W × D):
LS 300 S: 241 × 213 × 186 mm
– Power consumption (P
– Luminous flux (120°):
– Half-way angle:
– Efficiency:
– Power supply:
– Colour temperature:
– Average rated life expectancy:
L70B50 at 25°C: 36,000 hours
– Colour rendering index:
– Colour consistency SDCM:
– Luminous intensity distribution:
– Area illuminated to the front:
– Sensor technology (S onlyS):
– Sensor on standby (P
– Angle of coverage (S only):
240° with 180° angle of aperture
– Sensor unit swivelling range (S only):
– Floodlight adjusting range:
– Time setting (S only):
– Twilight setting (S only):
– Reach (S only):
– Mounting height (S only):
– IP rating:
– Protection class:
– Ambient temperature:
– Energy efficieny class:
an energy efficiency class "F" light source

4. Electrical installation

Connection
The supply lead is a 2 or 3-core cable:
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green / yellow)
Note:
The protective-earth conductor need not be con-
nected for this product.
LS 300: 218 × 213 × 184 mm
):
on
220 – 240 V, 50/60 Hz
4,000 K (neutral white)
starting value 6
LumEdit
202007061517_LS300_MIT_SENSOR_NW.LDT
120°
90°
60°
C0 / C180
20.04.21 / 15:23
passive infrared
) (S only):
sb
turns through ± 40°
vertically + 110° to -40°
10 s – 15 min
2 – 1,000 lux
max. 12 m
1.8 – 2 m
-10 °C to +30 °C
this product contains
Wiring diagram (Fig. 4.1)
The light source of this LED floodlight cannot be
replaced. If the light source needs to be replaced
(e.g. at the end of its service life), the complete LED
floodlight must be replaced.
29.50 W
2,704 lm
51°
92 lm/W
5. Installation
R
= 80
a
Polar Diagram
Touching live parts can result in electrical shock,
150°
180°
150°
burns or death.
120°
• Switch OFF power and interrupt power supply.
90°
100
• Using a voltage tester, check to make sure the
200
60°
300
light is disconnected from the power supply.
400
30°
30°
C90 / C270
cd / 1000 lm
• Make sure power supply remains interrupted.
355 cm²
1/1
Risk of damage to property!
0.50 W
Mixing up connection leads may produce a short
circuit.
• Identify connection leads.
± 80°
• Re-connect connection leads.
Preparing for installation
• Check all components for damage. Do not use
the product if it is damaged.
• Select an appropriate site to install the product.
– Take reach into consideration. (Fig. 5.1)
– Take reach and motion detection into consid-
eration. (Fig. 5.2, 5.3)
IP44
– Vibration-free.
I
– No obstacles in detection zone.
– Not in explosive atmospheres.
– Not on normally flammable surfaces.
– Do not look into the LED light from a short
distance (<20 cm).
– Installing LED floodlight in horizontal
position (± 15°).
• Correctly aiming LED floodlight. (Fig. 5.4)

Mounting procedure

• Check to make sure the power supply is
switched OFF. (Fig. 4.1)
• Detach plug-in terminal from wall mount.
(Fig. 5.5)
• Mark drill holes. (Fig. 5.6)
• Drill holes and fit ground plugs. (Fig. 5.7)
– 14 –
Hazard from electrical power.