4. Electrical installation

Hazard from electrical power.
Touching live parts can result in electrical shock,
burns or death.
• Switch OFF power and interrupt power supply.
• Using a voltage tester, check to make sure the
the power supply is disconnected.
• Make sure power supply remains interrupted.
Risk of damage to property!
Mixing up connection leads may produce a short
circuit.
• Identify connection leads.
• Re-connect connection leads.
Connecting the mains power supply lead
The supply lead is a 4-core cable:
L
= phase conductor (usually black, brown
or grey)
= Switched phase conductor (usually
black, brown or grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
Note:
The sealing plugs provided are intended for a mains
supply lead with an outer diameter of 5-10 mm.
Note:
The protective-earth conductor need not be
connected for this product.
Wiring diagram (Fig. 4.1)
5. Installation
Preparing for installation
• Check all components for damage. Do not use
the product if it is damaged.
• Select an appropriate site to install the product.
– Take reach into consideration. (Fig. 5.1)
– Take reach and motion detection into consid-
eration. (Fig. 5.2/5.3)
– Vibration-free.
– No obstacles in detection zone.
– Not in explosive atmospheres.
– Not on normally flammable surfaces.
Mounting procedure
• Check to make sure the power supply is
switched OFF. (Fig. 4.1)
• Unscrew retaining screw. (Fig. 5.4)
• Detach sensor switch from wall mount. (Fig. 5.5)
• Mark drill holes. (Fig. 5.6)
• Drill holes (Ø 6 mm) and fit wall plugs. (Fig. 5.7)
• Firmly screw wall mount into place.
– Concealed version (Fig. 5.8)
– Surface-mounted version with surface-
mounted wall base (Fig. 5.9)
• Connect mains power supply lead according
to terminal labelling. An additional external load
can be connected to N and . (Fig. 5.10)
• Plug in sensor connection plug. (Fig. 5.11)
• Fit sensor switch on wall mount. (Fig. 5.12)
• Tighten retaining screw. (Fig. 5.13)
• Switch ON power supply. (Fig. 5.13)
• Make settings ➜ "6. Function"
6. Function
Factory settings
Time setting: 5 seconds
Twilight setting: (daytime mode)
Reach: 100%
Steinel Connect app
To configure the sensor via smartphone or tablet,
you must download the STEINEL Connect app
from your app store. You will need a Bluetooth-