1� About this document
– Please read carefully and keep in a safe place.
– Under copyright.
Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
!
Disconnect the power supply before attempting any work on the sensor�
• During installation, the electric power cable to be connected must not be live.
Therefore, switch off the power first and use a voltage tester to make sure the
wiring is off-circuit.
• Installing the sensor involves work on the mains power supply. This work must
therefore be carried out professionally in accordance with national wiring regula-
tions and electrical operating conditions. ((DE- VDE 0100, AT- ÖVE-EN 1,
CH- SEV 1000)
3� IS 3360, IS 3360 MX, IS 345, IS 3180 COM1
Proper use
– IS 3360 MX and IS 345 MX are suitable for indoor ceiling mounting.
– IS 3360 MX and IS 345 MX are suitable for indoor- and outdoor ceiling mounting.
– IS 3180 is suitable for wall mounting indoors and outdoors.
– The concealed versions are only suitable for installing indoors.
The motion detector is equipped with pyro sensors that detect the invisible heat
emitted from moving objects (people, animals etc.). The heat detected in this way
is converted electronically into a signal that switches a connected load ON (e.g. a
light). Heat is not detected through obstacles, such as walls or panes of glass. Heat
radiation of this type will, therefore, not trigger the sensor.
26
Optionally, all function settings can be made via the RC5, RC8 remote controls
as well as the Smart Remote. (➔ "7� Accessories")
Package contents for concealed installation (Fig� 3�1)
Package contents for surface-mounted installation (Fig� 3�2)
Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed installation
C Designer trim, round or square
D Sensor module
E Half-round clip-on shroud
Product dimensions
Surface-mounted / concealed (Fig� 3�4)
IS 3360 IS, IS 3360 MX, IS 345
Surface-mounted / concealed (Fig� 3�5)
IS 345 MX
Surface-mounted / wall-mounted (Fig� 3�6)
IS 3180
4� Electrical installation
The mounting location should be at least 50 cm away from other lights because
heat radiated from these may activate the system.
An optional corner wall mount (product no. 648015 black or 035174 white) is
available for mounting the IS 3180.
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
= switched phase conductor (usually black, brown or grey)
Note on manual override function (Fig� 4�1):
A power switch for switching ON and OFF can be installed in the mains supply lead.
This is a prerequisite for the manual override function (➔ "6� Function")
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP 54) double seal cable gland.