About This Document; General Safety Precautions; Electrical Installation - STEINEL 032845 Instructions Manual

Table of Contents

Advertisement

GB

1. About this document

Please read carefully and keep in
a safe place�
– Under copyright. Reproduction
either in whole or in part only with
our consent.
– Subject to change in the interest
of technical progress.
Symbols
!
Hazard warning!
Reference to other
information in the
...
document�
2� General safety precautions
Disconnect the power
!
supply before attempting
any work on the unit�
• During installation, the electric
power cable to be connected
must not be live. Therefore,
switch off the power first and use
a voltage tester to make sure the
wiring is off-circuit.
• Installing the sensor involves work
on the mains power supply. This
work must therefore be carried
out professionally in accordance
with national wiring regula-
tions and electrical operating
conditions.
• Only use genuine replacement
parts.
• Repairs may only be made by
specialist workshops.
3� IS 360-1 DE
Proper use
– Sensor for recessing in indoor
and outdoor ceilings.
Movement triggers lights, alarms and
many other devices. For your con-
venience, safety and peace of mind.
The integrated pyroelectric infrared
detector senses the invisible heat ra-
diated from moving objects (people,
animals, etc.). The heat detected in
this way is converted electronically
into a signal that switches ON the
connected load. Heat is not detected
through obstacles, such as walls or
panes of glass, and will therefore not
activate the light.
The infrared sensor can be used
for switching light ON and OFF
automatically. The unit is not suitable
for burglar alarm systems as it is
not tamperproof in the manner
prescribed for such systems.
Package contents (Fig� 3�1)
Product dimensions (Fig� 3�2)
Product components (Fig� 3�3)
A Designer ring
B Lens / lens enclosure
C Twilight setting control dial
D Time setting control dial
E Clamping spring
F Terminal block compartment
Reach (Fig� 3�4)
- 22 -
4� Electrical installation
• Switch OFF power supply (Fig� 4�1)
The mains power supply lead is a
3-core cable:
L
= phase conductor (usually black,
brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor
(usually green/yellow)
Important: Incorrectly wired con-
nections will produce a short circuit
later on in the product or your fuse
box. In this case, you must identify
the individual cables and reconnect
them. An appropriate power switch
for switching ON and OFF can be
installed in the supply lead.
Important: After connecting the
power supply leads, always fit the
cable clamp or cable clip to relieve
strain on the cable. (Fig� 5�5)
The cable grip is suitable for cable
diameters of 8.5 mm to 10 mm.
Connection diagram (Fig� 4�1)
Fig� 4�1/a
Light without neutral conductor
Fig� 4�1/b
Light with neutral conductor
Fig� 4�1/c
Connection via two-circuit single-
interruption switch for manual and
automatic operation
Fig� 4�1/d
Connection via two-way switch for
manual override and automatic operation
Setting I: Automatic operation
Setting II: Manual operation, light
permanently ON
Note: The system can only be
switched OFF when installed as
shown in Fig� 4�1/c.
5� Mounting
• Check all components for damage.
• Do not use the product if it is
damaged.
• Select an appropriate mounting
location, taking the reach and
motion detection into consid-
eration (Fig� 5�1 / 5�2). The
most reliable way of detecting
movement is to install the sensor
aimed across the direction in
which a person would walk and
by ensuring that no obstacles
(such as trees, walls etc.) obstruct
the line of sensor vision.
Mounting procedure
• Switch OFF power supply.
• Drill ø 68 mm ceiling cut-out.
(Fig� 5�3)
• Connect conductors. (Fig� 5�4)
• Fit cable clamp or cable clip
to relieve strain on the cable.
(Fig� 5�5)
• Screw cover onto the terminal
block compartment. (Fig� 5�6)
• Set the clamping springs to the
upright position and fit the unit
into the ceiling cut-out. (Fig� 5�7)
• Switch ON power supply. (Fig� 5�7)
• Set functions ➜ "6� Function".
6� Function
Factory settings
Twilight level: 2000 lux
Time setting: 8 s
• Detach designer ring from the
enclosure. (Fig� 6�1)
• Unscrew the sensor (anticlock-
wise) to reach the control dial.
- 23 -