Product Dimensions; Electrical Installation; Function Operation - STEINEL LiveLink HF 3360 Information

Hide thumbs Also See for LiveLink HF 3360:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed
C Designer trim, round or square
D Sensor module

Product dimensions

Ceiling / wall mounting / surface-mounted and concealed wiring (Fig� 3�4)
4� Electrical installation
For wiring up the motion detector, the following applies: Under section 6 of
VDE 0100 520, a multiple-core lead containing both the mains voltage leads and
the control leads (e.g. NYM 5 × 1.5) may be used for the wiring between sensor and
LiveLink Box. The lead between LiveLink Box and sensor must be no longer than
300 m (for 1.5 mm²). After installing and switching on, the LiveLink Box takes approx.
45 seconds to start.
The sensor then starts to flash once per second during the initialisation cycle.
Wiring example (Fig� 4�1)
– Surface-mounted installation
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP54) double seal cable gland.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion detection
into consideration.
Installation procedure
Wall-mounting, concealed power supply lead (Fig� 5�1)
Ceiling mounting, concealed power supply lead (Fig� 5�2)
Wall-mounting, surface-mounted power supply lead (Fig� 5�3)
Ceiling mounting, surface-mounted power supply lead (Fig� 5�4)
For mounting on the wall, a water drainage hole (Ø 5 mm drill bit) is marked next to
the rubber seal. This must be opened if necessary. (Fig� 5�3)
18
An optional corner wall mount is available for mounting the HF 3360 LiveLink.
(Prod. no. 035174 white).
• Switch OFF power supply� (Fig� 5�1)
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply.
- Surface-mounted power supply lead (Fig� 5�5)
- Concealed power supply lead (Fig� 5�6)
• Insert fastening screws and mount load module.
• Fit sensor and load module together and screw into place.
• Switch ON power supply. (Fig� 5�6)
• Fit designer trim.
• Set functions. (➔ "6� Function")
• Detection zone / reach (Fig� 5�7)
6� Function / operation
Once you have connected the unit, closed the housing and fitted the lens, you are
ready to put the system into operation.
Master/slave
The HF 3360 LiveLink is suitable for use in master/slave networks. In this case, the
DALI sensor is the master, the LiveLink sensor the slave.
The master/slave configuration permits detection of movement in larger rooms or
spaces. The level of brightness prevailing in the room is only evaluated at the master.
The slaves report movements detected to the master. Lighting is switched ON and
OFF via the master only. As many as 30 users can be connected.
Wiring example (Fig� 6�1)
Important: The settings are made via the LiveLink Box via app.
– Twilight setting
– Time setting
– Semi/fully automatic
– Constant-lighting control
– Interconnecting several sensors
– Teach mode
– Test mode
– Daylight operation
– IQ mode
– Basic brightness
19

Advertisement

Table of Contents
loading

Table of Contents