Slow Rise And Slow Fall Parameter Area; Programming Mode Test Area; Output Parameter Reading And Setting Area - Raycus RFL-C30000M-CE User Manual

Continuous-wave fiber laser
Table of Contents

Advertisement

8.6.4 Slow rise and slow fall parameter area

The display menu of the laser power ramp up ramp down parameter setting area is shown in Figure 34.
Click Read Parameters to read the power rise and fall times stored in the laser. Click Set Parameters to set
a new power up and down time. When the rise and fall times are all set to 0, the power ramp up and ramp
down function is automatically turned off; When one is not 0, the ramp up or ramp down function is
automatically turned on, and the "ramp up environment mode" indicator in the status area is lit.
Figure 34 Display menu and measured waveform of power ramp up and ramp down setting area

8.6.5 Programming mode test area

The laser programming mode display menu is shown in Figure 35, where the program is written and
written to the laser (see Section 8.13 of this description for specific methods); In this interface, select the
program number, click Settings, and the "Program Mode" indicator in the status area will light up. Click
"Laser Emission ON", and the "Executing" indicator in the status area will light up. After the program
execution is completed, the "Executing Completed" indicator in the status area will light up. During the
execution process, click "Laser Emission OFF", and the "Executing Abnormality" indicator in the status
area will light up.

8.6.6 Output parameter reading and setting area

The display menu of the laser output parameter setting area is shown in Figure 36. The light output
parameter setting is invalid when the AD mode is turned on.
Figure 35 Laser Programming Mode Test Area Display menu