Raycus RFL-C30000M-CE User Manual page 28

Continuous-wave fiber laser
Table of Contents

Advertisement

Stop programming
A7
Mode
Set program
A8~A14
Number
A15
synchronous input
A16
COM
Laser-driven
C1
power supply
C2
Not connect
Select the optical
C3~C6
gate channel
Enable QCW
C7
mode
C8~C16
Not connect
B1
The laser is ready
B2
Laser output
XP1
The laser operates
B3
in internal mode
B4
Laser anomalies
Laser red light
B5
indication
B6
AD mode
Feedback signal of
B7
A1
Main power
B8
supply of laser
B9
Program running
In programming mode, program execution is
Input signal
terminated immediately when A7 is high.
Hardwired address for selecting a stored program
Input signal
number. A8 is the lowest bit and A14 is the
highest bit.
Synchronous input signal, used with the program
Input signal
command WAIT in programming mode.
Reference
Reference ground for all input signals of XP1.
ground
The rising edge turns on the main power, and the
Input signal
falling edge turns off the main power.
C3 is the lowest bit, C6 is the highest bit:
0000-close all optical gate channels;
0001-open channel 1;
Input signal
0010-open channel 2;
0011-open channel 3.
(For lasers with optical gate channels only, these pins
are spare in other lasers)
Enable QCW mode
Input signal
(For lasers with QCW modes only)
Output signal
The laser is ready to emit laser light when B1 is high.
Output signal
The laser is emitting light when B2 is high.
The laser works in the internal control mode when B3
Output signal
is high. In this mode, the laser can be controlled
by communication.
Output signal
The laser is abnormal when B4 is high.
Output signal
The laser is emitting guide light when B5 is high.
Output signal
The laser works in the AD mode when B6 is high.
Output signal
The laser has received the A1 signal when B7 is high.
Output signal
The main power of laser is on when B8 is high.
Output signal
Laser program is running when B9 is high.
27

Advertisement

Table of Contents
loading

Table of Contents