Raycus RFL-C30000M-CE User Manual page 22

Continuous-wave fiber laser
Table of Contents

Advertisement

Note: ①-REM/OFF/ON ②-POWER ③-LASER
④-ALARM ⑤-STOP ⑥-INDICATOR LIGHT
REM/OFF/ON: The key switch, the main control switch of the laser. Insert the key and turn it to the
"ON" position, the main control part of the laser is powered on, and the POWER light is on; Rotate to the
"REM" position, you need to close the 8 and 9 pins of the XP2 interface on the rear panel to realize
remote power-on, and rotate to REM to activate the hard-wired control mode of the laser.
POWER: Control power indicator, when the white indicator light is on, it means the main control
system is on.
LASER: The power button of the laser main power supply has a green light indicator function. After
the laser main control system is powered on and all INTERLOCKs are detected as normal, press this
button, the laser main power supply is powered on, and the button lights up after the main power supply
is powered on.
ALARM: INTERLCOK alarm indication, the ALARM indicator lights up during the power-on
self-check on the control panel. After the self-inspection is completed, all INTERLOCK interfaces are
normally closed, and the ALARM indicator is off. During the operation of the laser, if any INTERLOCK
is disconnected and the laser preparation is not completed, the indicator light will be on.
STOP: Emergency stop button, press to turn off the main power of the laser immediately; turn the
button clockwise to release the button, and press the LASER button again to start the main power of the
laser.
Figure 12 Front view of the panel
21

Advertisement

Table of Contents
loading

Table of Contents