Raycus RFL-C30000M-CE User Manual page 44

Continuous-wave fiber laser
Table of Contents

Advertisement

Set Diode Current (%)
The set value must be less than 100% and above
SDC
the minimum current setting value, which can be
set to 0. If the set value is greater than 100, the
default is input 100.
Read Current Set point
RCS
RPRR
Read Pulse Repetition Rate (Hz)
Read Board Temperature
RBT
RPW
Read Pulse Width (ms)
RCT
Read Laser Temperature
Reset Errors
PERR
SUT
Set Up Time (ms)
SDT
Set Down Time (ms)
RUT
Read Up Time (ms)
RDT
Read Down Time(ms)
PSRT
Program Start
PSTP
Program Stop
Enable Calibration Mode
–Power linear correction mode (in this mode, the
ECM
external analog is corrected and output after
filtering, so the response time of AD analog is
larger than that of through mode)
Send: 'SDC 100\r'
Return: 'SDC:100\r'
Other return values:
'ERR: Input Err\r'
'Laser is worked in AD Mode\r'
Send: 'RCS\r'
Return: 'RCS: 56.7\r'
(The current set value is 56.7 %)
Send: 'RPRR\r'
Return: 'RPRR:10\r'
(Repeat frequency is10Hz)
Send: 'RBT\r'
Return: 'RBT:36.6\r'
Send: 'RPW\r'
Return: 'RPW:5.5\r'
(pulse width is 5.5ms)
Send: 'RCT\r'
Return: 'RCT:34.5\r'
Send: 'PERR\r'
Return: 'PERR\r'
Send: 'SUT 50\r'
Return: 'SUT:50\r'
Send: 'SDT 50\r'
Return: 'SDT:50\r'
Send: 'RUT \r'
Return: 'RUT:50\r'
Send: 'RDT \r'
Return: 'RDT:50\r'
Send: 'PSRT 1\r'
Return: 'PSRT:1\r'
Send: 'PSTP\r'
Return: 'PSTP\r'
Send: 'ECM \r'
Return: 'ECM\r'