Raycus RFL-C30000M-CE User Manual page 29

Continuous-wave fiber laser
Table of Contents

Advertisement

B10
Program ending
Abnormal Wave
B11
Mode Termination
Synchronous
B12
output
B13
Warning output
B14
Not connect
External power
B15
supply (Positive
pole)
External power
B16
(Negative pole)
Current optical
D1~D4
gate channel
Water cooler
D5
warning
D6
Water cooler alarm
D7
QCW mode
Laser hardwire
D8~D11
address
D12~D16
Not connect
Laser program is ended when B10 is high. B10 clears
Output signal
when the A2 is invalid.
Laser program is ended abnormally when B11 is high.
Output signal
B11 can be cleared when the A4 is high.
Output signal
Sync signal output in programming mode.
Output signal
Laser is warning when B13 is high.
Input signal
The 24 V input voltage, power supply of all XP1
output signal. Only when B15 and B16 access
24 V power, output signal is effective.
Input signal
Indicates the current optical gate channel:
0000-all optical gate channels closed;
0001-channel1 opened;
Output signal
0010-channel 2 opened;
0011-channel 3 opened.
D1 is the lowest bit, D4 is the highest bit.
Indicates the current water temperature warning,
Output signal
indicating a risk of emitting laser.
(Used with Water Cooler)
Indicates the current water temperature alarm,
Output signal
prohibits laser emission.
(Used with Water Cooler)
Output signal indicating that the current laser operates
Output signal
in QCW mode
(For lasers with QCW mode only)
Set the laser hardwire address (Coding-Cable
function):
Output signal
0000- laser 0;
0001- laser1.