Raycus RFL-C30000M-CE User Manual page 20

Continuous-wave fiber laser
Table of Contents

Advertisement

e)
If ambient temperature is below -10℃, the chiller with both heating and cooling functions must
be used, and keep it in full-time operation;
Water cooling requirements for output optical cables:
a)
Water flow requirements: QP output cable water flow is between 3.0L/min and 4.0L/min;
b)
Water cooling pressure: 0.4Mpa~0.6Mpa at the water inlet;
c)
Water inlet and outlet connector type: M6 to ϕ8 quick-tightening connector QP);
d)
Water pipe type: outer diameter ϕ8 and inner diameter ϕ5.5(QP);
e)
Cooling water direction: unidirectional. The water pipe shall be connected in strict accordance
with the water inlet and outlet direction marked on the shell.
f) Cooling water quality: deionized water, distilled water, purified water; it is recommend to
replace once a month, and the replacement period should not exceed two months.
g)
PH value of cooling water: 5 ~8;
Figure 11 diagram of laser cooling system connection
19