4.4.3 Serial RS232 Interface

The 9-pin serial interface RS232 is used for the communication between the laser and the Raycus
software. It can be used to communicate with the Raycus software or the software of the Raycus software
which integrates the communication protocol of Raycus. The definition is as follows.
Pin No.

4.4.4 Analog Interface XP4

The analog interface, an 8-core Harting interface, is used to control the output power of the laser by
analog in AD mode, and can also monitor the output light and power feedback signals of the laser. The
interface definition is shown in Table 9 below.
Pin No.
Type
1
IN
2
AGND
3
OUT
4
Reference
5
OUT
6
Reference

4.4.5 ETHERNET Interface XP5

Table 8 RS232 serial interface definition
Type
2
IN
3
OUT
5
COM
Table 9 XP4 analog interface definition
0V~10 V analog signal, laser power control signal in AD mode ,
Table 10 XP5 communication interface definition
Pin No.
Function
1
2
3
4
5
6
7
8
Description
RXD, serial receiving pin of laser
TXD, serial transmitting pin of laser
GND, signal ground
Description
0V~10 V corresponding to 0%~100% output power
Analog signal ground
Power amplifier voltage output.
0 V: 0% laser power output;
8 V: 100% laser power output.
Reference ground for power amplifier voltage
High back-amplification voltage (reserve, no use)
Reference ground for high backup voltage (reserve, no use)
Description
TX+
Data transmission+
TX-
Data transmission-
RX+
Data acceptance+
N/C
Not connect
N/C
Not connect
RX-
Data acceptance-
N/C
Not connect
N/C
Not connect