Advertisement

Quick Links

ORCA-Fire
Digital CMOS Camera
C16240-20UP / C16240-20UP01
Instruction manual
Thank you for your purchase
Follow the safety precautions in Chapter 1 in order to avoid personal injury and
damage to property when using this camera. The manual describes the correct
handling method of the camera and provides instructions that should be
followed to avoid accidents. Read this manual carefully before using this
camera. After reading this manual, store it in a location where you can refer to
it at any time.
Ver.1.3
Oct. 2023
B5220301-03

Advertisement

Table of Contents
loading

Summary of Contents for Hamamatsu Photonics ORCA-Fire C16240-20UP

  • Page 1 ORCA-Fire Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual Thank you for your purchase Follow the safety precautions in Chapter 1 in order to avoid personal injury and • damage to property when using this camera. The manual describes the correct handling method of the camera and provides instructions that should be followed to avoid accidents.
  • Page 2 ~ Blank page ~...
  • Page 3: Safety Precautions

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 1. SAFETY PRECAUTIONS SYMBOLS The symbols shown below are used for this camera. Direct current Alternating current CLASSIFICATION OF WARNINGS We have classified the warnings symbols that appear in this instruction manual and on the camera as follows for your convenience.
  • Page 4 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 Power supply Use the camera with the indicated voltage on the rating sticker. Using a different voltage can damage the camera and lead to fire or electric shock. Cables Do not to place heavy objects on cables or bend them excessively. Doing so can damage the cables and lead to fire or electric shock.
  • Page 5 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 AC adapter When unplugging the power supply cord, do not pull on the cord. Remove the plug from the outlet to avoid causing electric shock or fire. When unplugging the power supply cord, do not pull on the cord, but remove the plug from the camera to avoid breakdown of the AC adapter or the camera.
  • Page 6 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 FCC Rules This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 7: Check The Contents Of Package

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 2. CHECK THE CONTENTS OF PACKAGE When opening the package, check that the following items are included before use. If the contents are incorrect, insufficient or damaged in any way, contact a Hamamatsu subsidiary or your local distributor before attempting to operate the camera.
  • Page 8: Installation

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 3. INSTALLATION Avoid using or storing this camera in the following places Places where the temperature is not the operating temperature indicated in the specifications • Places where the temperature is not the storage temperature indicated in the specifications •...
  • Page 9: Table Of Contents

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 Contents 1. SAFETY PRECAUTIONS ................... 1 SYMBOLS ........................... 1 CLASSIFICATION OF WARNINGS ..................1 2. CHECK THE CONTENTS OF PACKAGE ............5 3. INSTALLATION ....................6 4. OVERVIEW ......................9 5. FEATURES ......................9 6.
  • Page 10 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 13-1 IMAGE IS NOT TRANSFERRED ..................58 13-2 ALTHOUGH IMAGES ARE TRANSFFERED ..............58 14. SPECIFICATIONS .................... 59 14-1 CAMERA SPECIFICATIONS .................... 59 14-2 SPECTRAL RESPONSE CHARACTERISTICS (TYP.) ............ 62 15. DIMENSIONAL OUTLINES ................63 15-1 C16240-20UP ........................
  • Page 11: Overview

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 4. OVERVIEW The Digital CMOS camera (C16240-20UP / C16240-20UP01) utilizes a image sensor (scientific CMOS image sensor: sCMOS) using the latest CMOS design technologies and ultra-small semiconductor technologies and realizes low readout noise. The camera provides 10.5 megapixels resolution at 115 fps (frames/s) while achieving 1.0 electrons (rms) readout noise performance.
  • Page 12 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (7) Real-time correction functions There are a few pixels in CMOS image sensor that have brighter or darker intensity, when compared to surrounding pixels. The camera has a real-time variant (defective) pixel correction feature to further improve image quality.
  • Page 13 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (9) Camera readout modes The camera has two kinds of readout mode, Area readout mode and Lightsheet readout mode. The camera also has four readout direction in Lightsheet readout mode. (Camera readout modes) (Scan speed) (Readout direction) Area readout mode...
  • Page 14: Name And Function Of Parts

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 6. NAME AND FUNCTION OF PARTS (1) C16240-20UP (C-mount type) Figure 6-1 (2) C16240-20UP01 (F-mount type) Figure 6-2 Place the camera the ventilation ports to be lateral side. Do not place the •...
  • Page 15 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 Lens mount C16240-20UP can be attached to C-mount lens or an optics system. C16240-20UP01 can be attached to F-mount lens or an optics system. • The depth of the C-mount is 7 mm. Screwing in the C-mount too deeply might scratch the glass surface.
  • Page 16 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 • When a connection interface is changed from CoaXPress to USB, and vice versa, the application software must be closed and the camera must be turned off. • Do not connect CoaXPress and USB interface simultaneously. Air inlet / outlet These are the inlet and the outlet for the heat ventilation.
  • Page 17: Connection

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 7. CONNECTION Refer to the figure when connecting the various cables. (1) CoaXPress interface Figure 7-1 (2) USB interface Figure 7-2...
  • Page 18 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 Place the camera the ventilation ports to be upward. Do not place the rear • panel of the camera, which connectors are located, to be at the bottom (Do not block ventilation openings.). •...
  • Page 19: Base Plate

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 8. Base plate • Do this procedure on the stable working space and conditions. • Do not use other screws nor other wrench which were not included. ATTACHMENT OF BASE PLATE 1. Prepare a C16240-20UP. ...
  • Page 20: Removement The Base Plate

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 A hexagonal wrench is perpendicularly inserted to a screw. Fasten screws by hexagonal wrench while holding the camera. 3. Confirm the base plate is firmly fixed. 4. Attach the camera onto tripod or lab jack. REMOVEMENT THE BASE PLATE Remove the base plate in the reverse procedure of 8-1clause.
  • Page 21: Operations

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 9. OPERATIONS OPERATING PRECAUTIONS Be careful of the following when you operate the camera. (1) Cooling method Cooling of this equipment is done using a Peltier element. With a Peltier element, when current is supplied, one surface is cooled, and the other surface is heated.
  • Page 22: Preparating For Imaging

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 PREPARATING FOR IMAGING Use the following procedure when start operating the camera. • When you connect cables, turn off the power supply of the camera and the peripheral devices. • When using F-mount (C16240-20UP01), an F-mount adapter can be subject to light leaks due to the mating flange mechanism.
  • Page 23: Startup Dcam Configurator

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 STARTUP DCAM CONFIGURATOR The following is a procedure to startup “DCAM Configurator”. 1. Open “Setup.exe” in the DCAM-API software’s folder. If the DCAM-API software is not installed on your computer, insert the media of DCAM-API software in the slot of your computer.
  • Page 24 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 4. “DCAM Configurator” window is displayed. The startup is completed with this. - Even if the camera's power supply is turned off, the state of setting is kept. - The state of setting can confirm according to “Hardware” icon on DCAM Configurator window. - After the startup, operate DCAM Configurator according to "DCAM Configurator Instruction manual".
  • Page 25: Update Procedure Of Coaxpress Interface Board

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 UPDATE PROCEDURE OF COAXPRESS INTERFACE BOARD If you use an optional CoaXPress interface board, when the driver included in DCAM-API does not match the firmware version of the interface board, the following message prompting update of the interface board may be displayed.
  • Page 26: Description Of Cmos Image Sensor

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 10. DESCRIPTION OF CMOS IMAGE SENSOR 10-1 THEORY OF CMOS IMAGE SENSOR The pixel of a CMOS image sensor is composed of the photodiode and the amplifier that converts the charge into voltage. Entered light is converted to charge and converted to voltage in the pixel. The voltage of each pixel is output by switching the switch one by one.
  • Page 27: Readout Method Of Cmos Image Sensor

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 10-2 READOUT METHOD OF CMOS IMAGE SENSOR The CMOS camera adopts a rolling shutter readout for high speed imaging. In the camera, the odd and even lines are read out in pairs, therefore the exposure and readout timing is slightly delayed as the readout moves down the sensor (Figure 9-2).
  • Page 28 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (3) Over light Be careful not to input too strong light such as high-energy laser into CMOS • image sensor because CMOS image sensor may be damaged by over light.
  • Page 29: Description Of Various Functions

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11. DESCRIPTION OF VARIOUS FUNCTIONS 11-1 AREA READOUT MODE 11-1-1 CAMERA READOUT MODES (READOUT DIRECTION) The camera reads out in two line pairs simultaneously. Figure 11-1 Readout direction of Area readout mode 11-1-2 READOUT METHODS (1) Full resolution readout mode (1×1 readout) Perform charge readout from camera individually for all pixels.
  • Page 30 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-3 READOUT SPEED (SCAN SPEED) The readout speed can achieve a frame rate of 115 fps for full resolution with low noise (1.0 electrons (rms)) . The CoaXPress interface is required to transfer the full resolution image data at the full speed of 115 frames per second.
  • Page 31 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-4 FRAME RATE CALCULATION (1) CoaXPress Exp1 = 7.309 µs to 10 s (input in units of seconds) 1H = 7.309 µs Exp2 = ROUNDUP (Exp1 / 1H) * Round up to integer Vn1 = Number of vertical lines Vn2 = (Vn1 / 2) + 5 Conditions...
  • Page 32 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) USB Exp1 = 7.309 µs to 10 s (input in units of seconds) 1H = 7.309 µs Exp2 = ROUNDUP (Exp1 / 1H) * Round up to integer Hn1 = Number of horizontal lines (Binning OFF) BN = Binning setting Output bit depth BW = Interface band width...
  • Page 33 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 • The frame rate value is valid 3 digits and rounded down to 4th digit. • The calculation formula and the frame rate value of Start trigger mode (External trigger mode) are same as Free running mode.
  • Page 34 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-5 CONFIGURING EXPOSURE TIME The exposure time setting can be done by the units of seconds. The actual exposure time setting is defined by the following formula, and the camera automatically calculates a longer and closest value from the specified exposure time setting. Exp1 = 7.309 µs to 10 s (input in units of seconds) 1H = 7.309 µs Exp2 = ROUNDUP (Exp1 / 1H) * Round up to integer...
  • Page 35 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-6 CAMERA OPERATION MODES 11-1-6-1 Free running mode The camera has Free running mode which the exposure and readout timing can be set and controlled by an internal microprocessor. Free running mode has normal readout mode (in which the exposure time is longer than the 1 frame readout time) and electrical shutter mode (in which the exposure time is shorter than the 1 frame readout time).
  • Page 36 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) Electrical shutter The electrical shutter mode is used to get a proper signal level when signal overflow happens due to too much input photons in normal readout mode. In this mode, the fastest frame rate is 115 fps (Via CoaXPress), 15.7 fps (Via USB) at full resolution even when the exposure time is short.
  • Page 37 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-6-2 External trigger mode The camera has various external trigger functions to synchronize the camera with the external equipment. In External trigger mode, the external equipment becomes a master and the camera becomes a slave.
  • Page 38 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) Global reset Edge trigger mode Global reset function enables to reset the electric charge of all pixels at the same time. Then all pixels can start exposure at the same time. With this Global reset Edge trigger mode, the exposure of all pixels begins on the edge (rising / falling) timing of the input trigger signal into the camera.
  • Page 39 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (3) Level trigger mode The Level trigger mode is used to control both exposure start timing and exposure time length by inputting external trigger pulses. In this mode, the camera starts exposure at the start of high or low period of the input trigger pulse and stops exposure at the end of high or low period of the input trigger pulse.
  • Page 40 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (4) Global reset Level trigger mode Global reset function enables to reset the electric charge of all pixels at the same time. Then all pixels can start exposure at the same time. The example below is for the trigger level High.
  • Page 41 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (5) Synchronous readout trigger mode The Synchronous readout trigger mode is used for continuous imaging when it is necessary to control the exposure start timing of each frame from an external source. It is useful for confocal microscopy.
  • Page 42 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 Trigger Times; Also in the Synchronous readout trigger mode, synchronous readout can be controlled by specifying, the number of timing pulses to determine the exposure time. The input trigger is valid only during the trigger ready is enabled. The following figure shows the exposure timing when the Trigger Times is set as 4.
  • Page 43 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-6-3 Start trigger mode Start trigger mode is to start operating the camera by a trigger input for a continuous imaging. It is useful to secure the frame rate as fast as possible when continuous image acquisition and not to sacrifice the exposure time.
  • Page 44 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-1-7 TIMING OUTPUT The camera provides a range of trigger output signals to synchronize with an external instrument and the camera becomes the master and the external instrument becomes the slave. There are four different trigger output functions as follows. - Global exposure timing output - Any low exposure timing output - Programmable timing output...
  • Page 45 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 External trigger 0(H) 1(H) ・  ・  ・  N-1(H) N(H) Sensor readout Read end Delay Width Vsync Delay Width Trigger Delay Width Figure 11-12 Programmable timing output (4) Trigger ready output The trigger ready output is useful to make the frame intervals as short as possible in external trigger mode.
  • Page 46: Lightsheet Readout Mode

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2 LIGHTSHEET READOUT MODE Lightsheet Readout Mode is a unique feature of CMOS image sensor which provides improved control over the rolling shutter mechanism. By finely synchronizing the camera readout with the illumination scan, scattered light is rejected allowing images of higher signal to noise ratios to be acquired.
  • Page 47 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2-2 ABOUT READOUT AT LIGHTSHEET READOUT MODE (1) Readout methods This mode can set Sub-array readout. Binning readout mode is not supported. The minimum selectable steps of size and position of sub-array can be configured according to the table below.
  • Page 48 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2-3 FRAME RATE CALCULATION (1) CoaXPress Exp1 = 7.309 µs to 276.9 ms (input in units of seconds) 1H = 7.309 µs to 233.9 µs Exp2 = ROUNDUP (Exp1 / 1H) * Round up to integer Vn1 = Number of vertical lines Vn2 = (Vn1 / 2) + 5 Operation modes...
  • Page 49 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) USB Exp1 = 7.309 µs to 276.9 ms (input in units of seconds) 1H = 7.309 µs to 233.9 µs Exp2 = ROUNDUP (Exp1 / 1H) * Round up to integer Hn1 = Number of horizontal lines Output bit depth BW = Interface band width...
  • Page 50 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2-4 READOUT TIME OF THE HORIZONTAL LINE Readout time and exposure time can be varied with Lightsheet Readout Mode for synchronizing the camera readout with the illumination scan. = Number of vertical lines = 7.309 µs to 233.9 µs Readout time = (Vn / 2 + 5) ×...
  • Page 51 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2-5 TIMING DIAGRAM (1) Free running mode Internal exposure timing setting 0(H) 1(H) ・  ・  ・  N-1(H) N(H) Sensor readout CoaXPress data output USB data output Any-row exposure timing output 1H readout time : 7.309 μs – 233.9 μs Figure 11-17 (Ex.
  • Page 52 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) Edge trigger mode (External trigger mode) External trigger Internal exposure timing setting 0(H) 1(H) ・  ・  ・  N-1(H) N(H) Sensor readout CoaXPress data output USB data output Any-row exposure timing output Trigger ready output (CoaXPress) Trigger ready output (USB) * Delay: 4H, Jitter: ≦...
  • Page 53 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (3) Start trigger mode External trigger Internal exposure timing setting 0(H) 1(H) ・  ・  ・  N-1(H) N(H) Sensor readout CoaXPress data output USB data output Any-row exposure timing output Trigger ready output (CoaXPress) Trigger ready output (USB) * Delay: 4H, Jitter: ≦...
  • Page 54 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-2-6 TRIGGER OUTPUT The camera provides a range of trigger output signals to synchronize with an external instrument and the camera becomes the master and the external instrument becomes the slave. There are three different trigger output functions as follows. - Any row exposure timing output - Programmable timing output - Trigger ready output...
  • Page 55 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 External trigger 0(H) 1(H) ・  ・  ・  N-1(H) N(H) Sensor readout Read end Delay Width Vsync Delay Width Trigger Delay Width Figure 11-23 Programmable timing output (Top to bottom readout) External trigger 0(H) 1(H) ・ ...
  • Page 56: Real-Time Defect Pixel Correction

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-3 REAL-TIME DEFECT PIXEL CORRECTION CMOS image sensors have pixels with high dark current caused by the failure of the silicon wafer, which appear as white spots with long exposure time. The camera has real-time pixel correction features to improve image quality.
  • Page 57: Data Reduction Functions

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-4 DATA REDUCTION FUNCTIONS The camera provides 10.5 megapixels resolution at 115 fps and 16 bit of gradation. Then the camera outputs 2.4 GB of data per second, and large capacity of storage device would be necessary to store such a large amount of data.
  • Page 58: Master Pulse

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 11-5 MASTER PULSE The camera has master pulse function which can generate pulses that is independent of the exposure or readout timing of image sensor. External trigger mode can work synchronized with the timing pulses that the master pulse generates, except for External trigger mode in Lightsheet Readout Mode.
  • Page 59: Maintenance

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 12. MAINTENANCE 12-1 CARE Perform cleaning of this equipment with the dry soft cloth. • Do not wipe with a damp cloth or unclean cloth. Then, the glass window on the image sensor should be cleaned according to the following. 1.
  • Page 60: Troubleshooting

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 13. TROUBLESHOOTING If an abnormality occurs, look up the possible causes in the following tables and, if necessary, report the details to Hamamatsu subsidiary or your local distributor. 13-1 IMAGE IS NOT TRANSFERRED Cause Measures Chapter...
  • Page 61: Specifications

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 14. SPECIFICATIONS 14-1 CAMERA SPECIFICATIONS (1) Image quality specifications Imaging device sCMOS image sensor Effective number of pixels 4432 (H) × 2368 (V) Pixel size 4.6 μm × 4.6 µm Effective area 20.387 mm ×...
  • Page 62 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (2) Functional specifications Sensor mode Area readout / Lightsheet readout Readout mode Full resolution readout / Binning readout * / Sub-array readout * Exposure time 7.309 µs ~ 10 s (7.309 µs step) Readout time * 3, 4 8.695 ms...
  • Page 63 Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 1 Digital binning, 2×2, 4×4. At Area readout mode. 2 Minimum settable step of the size and position are as follows: It is in only the case that the camera is used with DCAM-API. Horizontal size Vertical size Horizontal position...
  • Page 64: Spectral Response Characteristics (Typ.)

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 (7) Applicable standards EN61326-1: 2013 Class A Emission limits: CISPR 11 Group1 Class A Immunity requirements: Table2 Function performance and operation ± Intensity fluctuation of image is within 5 %. mode in immunity tests Exit the image acquisition software, turn off the Restoration procedure in immunity power of camera and focus adjustment unit.
  • Page 65: Dimensional Outlines

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 15. DIMENSIONAL OUTLINES 15-1 C16240-20UP (Unit: mm)
  • Page 66: C16240-20Up01

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 15-2 C16240-20UP01 (Unit: mm) 15-3 BASE PLATE...
  • Page 67: Warranty

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 16. WARRANTY Hamamatsu Photonics have fully inspected this camera and checked that its performance conforms to specifications. In the unlikely event of a breakdown or other malfunction, contact a Hamamatsu subsidiary or your local distributor.
  • Page 68: Contact Information

    Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3 17. CONTACT INFORMATION Manufacturer HAMAMATSU PHOTONICS K. K., Systems Division 812 Joko-cho, Higashi-ku, Hamamatsu City, Shizuoka Pref., 431-3196, Japan Telephone (81) 53-431-0124, Fax: (81) 53-435-1574 E-mail: export@sys.hpk.co.jp Local contact information worldwide can be found at: www.hamamatsu.com...

This manual is also suitable for:

Orca-fire c16240-20up01

Table of Contents