Digital CMOS Camera C16240-20UP / C16240-20UP01 Instruction manual_Ver.1.3
Lens mount
C16240-20UP can be attached to C-mount lens or an optics system.
C16240-20UP01 can be attached to F-mount lens or an optics system.
The depth of the C-mount is 7 mm. Screwing in the C-mount too deeply might
scratch the glass surface.
Trigger input connector [EXT.TRIG]
This is used when the camera is being operated using external synchronization.
Input is TTL or 3.3 V LVCMOS level, and input impedance is 10 kΩ.
When an external trigger is input, the trigger is activated at the falling or rising edge of the signal. (You
can choose external trigger polarity between Negative and Positive.)
Timing out connector 1,2,3 [TIMING 1,2,3]
This is used when peripheral device(s) require synchronization with the camera.
Output is 3.3 V LVCMOS level. Output impedance is 33 Ω.
Determine termination according to cable length and so on.
CoaXPress interface connector 1 - 4 [CoaXPress 1 - 4]
The connector 1 to 4 are connected to the CoaXPress interface connector 1 to 4 on the computer,
respectively.
When a connection interface is changed from CoaXPress to USB, and vice versa,
the application software must be closed and the camera must be turned off.
Do not connect CoaXPress and USB interface simultaneously.
STATUS lamp [STATUS]
The LED indicates status of camera.
Lighting color
Turn off
Orange
Green
Orange
Red
Power switch [POWER]
The power is turned on/off.
- When the power switch is set to "ON", the camera turns on and starts initialization and the lamp blinks
in orange.
- When the initialization is completed, the lamp color stays in green.
- When the camera transfers data, and the lamp color turns orange.
- When the power switch is set to "OFF", the camera returns to the power off state and the lamp turns
off.
DC power input connector [DC IN]
This is the power supply terminal. Use the accessory AC adapter.
USB interface connector [USB 3.1 Gen 1]
This is connected to the USB interface connector on the computer.
Status of power distribution
(no color)
(Blinking)
Initialization
(lighting)
(lighting)
Data transfer
(lighting)
When the camera heats up, stop operation and unplug the
AC adapter immediately.
Power off
Power on
Heat up
13