Mitsubishi Electric FR-CS82S-025 Instruction Manual page 240

Hide thumbs Also See for FR-CS82S-025:
Table of Contents

Advertisement

8.2
Common specifications
Control method
Output frequency range 
Frequency 
Analog input
setting and 
resolution
Digital input
Analog input
Frequency 
accuracy
Digital input
Voltage/frequency 
characteristics
Starting torque
Torque boost
Acceleration/deceleration 
time setting 
DC injection brake
Stall prevention operation 
level
Analog input 
Frequency 
(2)
setting 
signal
Digital input
Start signal
Input signal (5)
Operational function
Output signal
relay output (1)
Operation 
Status 
panel
monitoring
Fault record
Parameter 
unit (FR-
PU07)
Interactive 
guidance
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control, General-purpose
magnetic flux vector control, Optimum excitation control).
0.2 to 400 Hz.
0.06/60 Hz at 0 to 10 V / 10 bits (terminals 2 and 4).
0.12/60 Hz at 0 to 5 V / 9 bits (terminals 2 and 4).
0.06/60 Hz at 0 to 20 mA / 10 bits (terminal 4).
0.01 Hz.
Within ±1% of the maximum output frequency at 25°C (±10°C).
0.01% or less of the set output frequency.
Base frequency can be set from 0 to 400 Hz. Constant-torque or adjustable 3 points V/F can be selected.
150% or more at 1 Hz, with General-purpose magnetic flux vector control and slip compensation.
Manual torque boost.
0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/
deceleration modes are available.
Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable.
Operation current: 0 to 200% variable, with selectable availability of the function.
Terminal 2: 0 to 10 V / 0 to 5 V.
Terminal 4: 0 to 10 V / 0 to 5 V / 4 to 20 mA.
Input from the PU, with selectable frequency setting increments.
Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Using Pr.178 to Pr.182 (input terminal function selection), the signal can be selected from the
following:
Multi-speed selection, Remote setting, Second acceleration/deceleration function selection, Terminal 4
input selection, JOG operation selection, PID control valid terminal, External thermal relay input, Output
stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset,
Traverse function selection.
Maximum frequency, minimum frequency, frequency jump operation, external thermal relay input
selection, automatic restart after instantaneous power failure operation, forward/reverse rotation
prevention, remote setting, second acceleration/deceleration function, multi-speed operation,
regeneration avoidance, slip compensation, operation mode selection, offline auto tuning, PID control,
computer link operation (RS-485 communication), Optimum excitation control, power failure stop,
MODBUS RTU, increased magnetic excitation deceleration.
Using Pr.195 output terminal function selection, the signal can be selected from the following:
Inverter running, Up to frequency, Overload warning, Output frequency detection, Electronic thermal O/
L relay pre-alarm, Inverter operation ready, Output current detection, PID lower limit, PID upper limit,
PID forward/reverse rotation output, Heatsink overheat pre-alarm, During deceleration at occurrence of
power failure, During PID control activated, PID output interruption, During retry, Alarm output, Fault
output, Fault output 3.
Selectable from the following:
output frequency, output current(steady state), output voltage, frequency setting, cumulative
energization time, actual operation time, converter output voltage, electronic thermal relay function load
factor, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor,
output power, cumulative power, motor thermal load factor, inverter thermal load factor.
Fault record is displayed when a protective function is activated. Past 8 fault records are stored.
(output voltage, output current, frequency, and cumulative energization time right before the protective
function is activated.)
Help function for operation guide
*1
.
239
8. SPECIFICATIONS
8.2 Common specifications
3
2
3
4
5
6
7
8
9