8
SPECIFICATIONS
This chapter explains the specifications of this product.
Always read the instructions before use.
8.1
Inverter rating
 Three-phase 400 V class
Model FR-CS84-[]
Applicable motor capacity (kW)
*2
Rated capacity (kVA)
*3
Rated current (A)
Overload current rating
*5
Rated voltage
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.
*2
The rated output capacity assumes that the output voltage is 440 V.
*3
When using the inverter at the surrounding air temperature of 50°C, the rated current is decreased to the value shown in the parentheses.
*4
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or fall below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
*6
The power supply capacity is the value at the rated output current. The input power impedances (including those of the input reactor and cables)
affect the value.
 Single-phase 200V class
Model FR-CS82S-[]
Applicable motor capacity (kW)
*2
Rated capacity (kVA)
*3
Rated current (A)
Overload current rating
*5
Rated voltage
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.
*2
The rated output capacity assumes that the output voltage is 230 V.
*3
When using the inverter at the surrounding air temperature of 50°C, the rated current is decreased to the value shown in the parentheses.
*4
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load. If the automatic restart after instantaneous power failure
function (Pr. 57) or power failure stop function (Pr. 261) is set and power supply voltage is low while load becomes bigger, the bus voltage
decreases to power failure detection level and load of 100% or more may not be available.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
*6
The power supply capacity is the value at the rated output current. The input power impedances (including those of the input reactor and cables)
affect the value.
238
8. SPECIFICATIONS
8.1 Inverter rating
012
022
036
*1
0.4
0.75
1.5
2.2
0.9
1.7
2.7
3.8
1.2
2.2
3.6
5.0
(1.0)
(1.9)
(3.1)
(4.3)
*4
150% 60 s, 200% 0.5 s (inverse-time characteristics).
Three-phase 380 to 480 V.
Three-phase 380 to 480 V, 50/60 Hz.
325 to 528 V, 50/60 Hz.
±5%
*6
1.5
2.5
4.5
5.5
Open type (IP20).
Natural.
0.6
0.6
0.9
0.9
025
042
*1
0.4
0.75
1.0
1.7
2.5
4.2
(2.1)
(3.6)
150% 60 s, 200% 0.5 s
*4
(inverse-time characteristics).
Three-phase 200 to 240 V.
Single-phase 200 to 240 V, 50/60 Hz
170 to 264 V, 50/60 Hz.
±5%
*6
1.5
2.3
Open type (IP20).
Natural.
0.6
0.6
050
080
120
160
230
3.7
5.5
7.5
11
15
6.1
9.1
12.2
17.5
22.5
8.0
12.0
16.0
23.0
29.5
(6.8)
(10.2)
(13.6)
(19.6)
(25.1)
9.5
12.0
17.0
20.0
28.0
Forced air.
1.4
1.9
1.9
3.5
3.5
070
100
1.5
2.2
2.8
4.0
7.0
10.0
(6.0)
(8.5)
4.0
5.2
Forced air.
1.4
1.4
295
2
.
2
.