 Operation mode selection flow
Referring to the following table, select the basic parameter settings or terminal wiring related to the operation mode.
Method to give
Frequency setting
start command
Input with the external
signal (via terminal 2, 4, or
JOG, or using the multi-
speed selection function,
etc.)
Input with the
external signal
Input from the PU (digital
(via terminal STF/
setting)
STR)
Input through
communication (via the PU
connector)
Input with the external
signal (via terminal 2, 4, or
JOG, or using the multi-
speed selection function,
etc.)
Input from the PU
Input from the PU (digital
setting)
Input with the external
signal (via terminal 2, 4, or
JOG, or using the multi-
speed selection function,
etc.)
Input through
communication
Input from the PU (digital
(via the PU
setting)
connector)
Input through
communication (via the PU
connector)
 External operation mode (Pr.79 = "0" (initial value) or "2")
• Select the External operation mode when the start command and the frequency command are applied from a frequency
setting potentiometer, start switch, etc. which are provided externally and connected to the control circuit terminals of the
inverter.
• Generally, parameter change cannot be performed in the External operation mode. (Some parameters can be changed.
Refer to
on
page
89.)
Pr.77
• When
= "0 or 2", the inverter starts up in the External operation mode at power-ON. (To start up the inverter in the
Pr.79
Network operation mode, refer to
• When parameter changing is seldom necessary, setting "2" fixes the operation mode to the External operation mode.
Input terminal
method
Terminal STF (for forward
rotation) / STR (for
reverse rotation) (refer to
page
145),
terminal 2 (analog), 4
(analog), RL, RM, RH,
JOG, etc.
Terminal STF (for forward
rotation) / STR (for
reverse rotation) (refer to
page
145.)
Terminal STF (for forward
rotation) / STR (for
reverse rotation) (refer to
page
145),
terminals for RS-485
communication
Terminal 2 (analog), 4
(analog), RL, RM, RH,
JOG, etc.
Terminals for RS-485
communication,
terminal 2 (analog), 4
(analog), RL, RM, RH,
JOG, etc.
Not available
page
104.)
Parameter setting
• Frequency setting:
Pr.79 = "2"
Turn ON a signal for frequency
(External operation
setting
mode fixed)
• Start command:
Turn ON the STF/STR signal
• Frequency setting:
Pr.79 = "3"
Digital setting
(External/PU combined
• Start command:
operation mode 1)
Turn ON the STF/STR signal
• Frequency setting:
Transmit a frequency command
Pr.338 = "1"
via communication.
Pr.340 = "1 or 2"
• Start command:
Turn ON the STF/STR signal
• Frequency setting:
Pr.79 = "4"
Turn ON a signal for frequency
(External/PU combined
setting
operation mode 2)
• Start command:
Press the RUN/FWD/REV key
• Frequency setting:
Pr.79 = "1"
Digital setting
(PU operation mode
• Start command:
fixed)
Press the RUN/FWD/REV key
• Frequency setting:
Turn ON a signal for frequency
Pr.339 = "1"
setting
Pr.340 = "1 or 2"
• Start command:
Transmit a start command via
communication
• Frequency setting:
Transmit a frequency command
via communication.
Pr.340 = "1 or 2"
• Start command:
Transmit a start command via
communication
5.5 (D) Operation command and frequency command
Operation method
10
103
5. PARAMETERS
2
2
3
4
5
6
7
8
9