Figure 8 Routing the wires
c Attach the correct mating connector to avoid exposure to live
wires.
4. Connect the other end of the AC input cable to the circuit
breaker in the AC distribution panel supplying AC power to
the unit.
975-1175-01-01
Step 5: Connecting AC Output
Cables to an Existing AC Circuit
ELECTRIC SHOCK AND FIRE HAZARDS
Make sure wiring is disconnected from all electrical sources
n
before handling. All wiring must be done in accordance with
local and national electrical wiring codes.
A manufacturer-tested and approved GFCI must be
n
connected to the Freedom XC AC output, and GFCI
protection must be provided on every receptacle connected
to the AC hard wired installation. Other types may fail to
operate properly when connected to the Freedom XC. See
Ground Fault Circuit Interrupters (GFCIs) on page 18.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
Basic Installation Procedures
WARNING
25