Connecting To Ac Wiring - Xantrex Truecharge TC20+ Owner's Manual

Truecharge 20+/40+ amp multistage battery charger
Table of Contents

Advertisement

8. Before proceeding, carefully check the wiring polarity – make sure
.
9. To make a single battery bank connection:
10. To make multiple battery bank connections using a DC negative bus:
11. Fully insert the negative wire into the negative terminal on the

Connecting to AC Wiring

To connect AC wiring:
1. Make sure the AC source circuit is disconnected by turning off the
2. Plan the routing the AC wiring will follow from the source (usually a
the positive on the charger is going to the positive on the batteries
(fuse or breaker) and make sure the negative on the charger is going
to the battery negative terminal (or engine negative bus or DC
negative bus). Do not reverse the connections.
If you reverse the polarity of any one of the DC connections, the
internal fuse for that output bank opens. A qualified technician must
replace this fuse for that bank to function. The other banks should
continue to function normally.
• Connect the negative cable to the battery negative terminal
• Fully insert the negative wire into the negative terminal on the
charger
(Figure
2-3,14). Make sure there are no stray wire strands
protruding from the terminal. Tighten the connector (20 in-lbs
torque) and test that the wire is secure.
• Connect up to three negative cables to the DC negative bus or
engine negative bus
• Connect each negative cable to the battery negative terminal
(Figure
2-3, 10, 11, 12)
• Connect a negative cable from the DC negative bus to the negative
terminal on the Truecharge+
charger
(Figure
2-3, 14). Check all connections for tightness and to
ensure the conductors are fully inserted in their terminals with no
stray wire strands protruding. Tighten the connector (20 in-lbs torque
recommended) and test that the wire is secure.
breaker feeding the circuit, unplugging from shorepower and
disconnecting any other power sources such as a generator.
15 amp breaker in an AC distribution panel) to the charger. Measure
the required length of three-conductor No. 14 AWG wire, and cut it.
Allow some extra length for connections and to provide slack.
(Figure
2-3, 7,8,9), one for each battery bank.
(Figure
2-3, 13, 14).
Installing Truecharge+
2–11