Xantrex Freedom XC 1800 Owner's Manual page 79

12vdc inverter charger
Table of Contents

Advertisement

Table 13 Error codes displayed on the LCD screen
Error Code
Condition
Low battery voltage
shutdown is imminent
depending on the setting,
E01
see Maintaining the
Freedom XC Unit on page
61.
AC output overload
E03
shutdown
E04
Over-temperature shutdown
E06
AC output overload warning
975-1175-01-01
Mode
Check battery status and recharge if necessary.
Battery mode
Check for proper DC cable sizing.
(inverting)
Check for loose connections and tighten if necessary.
Reduce the loads connected to the AC outlet of the unit.
Battery mode
Check appliances that have high-surge ratings and disconnect
(inverting)
if necessary.
Reduce the loads connected to the AC outlet of the unit.
Battery mode
Check that the ventilation grille is not blocked.
(inverting)
Check for ambient temperature and move the unit to a cooler
location whenever possible.
Battery mode
Reduce the loads connected to the AC outlet of the unit.
(inverting)
Warning Messages
Action
65