System Specifications

System Specifications
Table 18 System specifications
a
Transfer relay rating (A
)
Transfer time (milliseconds
   Shore to inverter:
   Inverter to shore:
Transfer voltage (V)
   Shore to inverter:
   Inverter to shore:
Cooling
a
 Circuit breakers shall not carry more than 80% of their UL rating continuously.
b
 To change the AC Transfer time (mode), see Adjusting Feature Settings in Configuration Mode on page
43.
74
Freedom XC 1800 (12VDC)
20A
b
)
<20 milliseconds
<20 milliseconds with a 20-
second delay
<85 V and >140 V
<135 V and >90 V
Fan, activated by any of the
following:
High internal temperature
High AC output power
Table 19 DC input for inverting
Operating voltage range
Maximum non-operating voltage 24 VDC
Nominal voltage
Nominal current at full load
Table 20 AC output for inverting
Output voltage options
b
Continuous power
Continuous current
Surge power (2 sec)
c
Frequency
GFCI protection downstream
Wave shape
Peak efficiency
Full load efficiency
a
To set LBCO, see Adjusting Feature Settings in Configuration Mode on page 43.
b
 Power derates to 85% when output voltage is set to 110/108 VAC (120VAC default).
c
 To set the AC Frequency, see Adjusting Feature Settings in Configuration Mode on page 43.
Freedom XC 1800 (12VDC) Owner's Guide
Freedom XC 1800 (12VDC)
a
LBCO voltage
–18.0 VDC
12 VDC
173 ADC
Freedom XC 1800 (12VDC)
120, 110, 108 VAC
1800 W @ 40 °C
15 A
rms
3600 W
60 (or 50) Hz
Required (customer-provided)
True sine wave
91%
≥ 87.5%