Basic Installation Procedures
NOTICE
EQUIPMENT DAMAGE
Make sure the wires are connected properly. The AC wiring
terminal blocks are split into input and output sections.
Failure to follow these instructions can result in equipment
damage.
When making the AC input and AC output connections, observe the
correct color code for the appropriate AC wire, as described inTable
8 below.
Table 8 Color codes for typical AC wiring
Color
Black/Red/Brown
White/light blue
Green, green/yellow, or bare
copper
24
AC Wire
Line
Neutral
Ground
NOTICE
REVERSE POLARITY DAMAGE
Make sure the wires are connected properly. Improper connections
(connecting a line conductor to a neutral conductor, for example)
will cause the Freedom XC to malfunction and may permanently
damage the inverter/charger. Damage caused by a reverse polarity
connection is not covered by your warranty.
Failure to follow these instructions can result in equipment
damage.
AC Input Connections
To make a connection:
1. Ensure AC and DC power sources are turned off.
2. Install the required circuit breaker in the AC distribution
panel supplying AC power to the unit.
3. Attach the compatible connector from the AC input cable to
the receptacle on the unit as shown.