4.1.2

List of parameters classified by purpose of use

Set the parameters according to the operating conditions. The following list indicates purpose of use and
corresponding parameters.
Purpose of Use
Adjustment of acceleration/deceleration time and
pattern
Selection of optimum output characteristic for load
characteristic
Limit of output frequency
Operation over 60Hz
Adjustment of frequency setting signal and output
Adjustment of motor output torque
Adjustment of brake operation
Multi-speed operation
Jog operation
Frequency jump operation
Automatic restart after instantaneous power failure
Optimum acceleration/deceleration within continuous
rating range
Stall prevention of motor, lift operation
To perform commercial power supply-inverter switch-
over operation
Timing of magnetic brake operation
Reversible operation according to analog signal
polarity
Advanced magnetic flux vector control operation
Sub-motor operation
To make desired output characteristics (V/F pattern)
Operation via communication with personal
computer
Operation under PID control
To make backlash compensation
To detect current
Programmed operation
High-speed frequency control operation
To exercise stop-on-contact control
To exercise droop control
To suppress noise
Calibration of frequency meter
Adjustment of digital frequency meter
Display of speed, etc.
Clearing of inverter's actual operation time
Alarm code output selection
Function rewrite prevention
Reverse rotation prevention
To group parameters
To set initial values for parameters
To decelerate inverter to a stop at power failure
Assignment of input terminal functions
Assignment of output terminal functions
To increase cooling fan life
Motor overheat protection
Automatic restart after alarm stop
Selection of key beep
Inverter reset selection
Output phase failure protection selection
To determine the replacement time of capacitor
Pr. 7, Pr. 8, Pr. 20, Pr. 21
Pr. 3
Pr. 1, Pr. 2 Pr. 18
Pr. 903, Pr. 905
Pr. 73, Pr. 902, Pr. 903, Pr. 904, Pr. 905
Pr. 0, Pr. 80, Pr. 81
Pr. 10, Pr. 11, Pr. 12
Pr. 4, Pr. 5, Pr. 6, Pr. 24, Pr 25, Pr. 26, Pr. 27, Pr. 232, Pr. 233, Pr. 234,
Pr. 235, Pr. 236, Pr. 237, Pr. 238, Pr. 239
Pr. 15, Pr. 16
Pr. 31, Pr. 32, Pr. 33, Pr. 34, Pr. 35, Pr. 36
Pr. 57, Pr. 58, Pr. 611
Pr. 60
Pr. 156
Pr. 135 to Pr. 139
Pr. 42
Pr. 28, Pr. 73
Pr. 80, Pr. 81
Pr. 0, Pr. 3, Pr. 7, Pr. 8, Pr. 44, Pr. 45, Pr. 46, Pr. 47, Pr. 110, Pr. 111,
Pr. 112, Pr. 113
Pr. 100 to Pr. 109
Pr. 117 to Pr. 124, Pr. 342
Pr. 128 to Pr. 134
Pr. 140 to Pr. 143
Pr. 150 to Pr. 153
Pr. 200 to Pr. 231
Pr. 271 to Pr. 274
Pr. 275, Pr. 276
Pr. 286, Pr. 287
Pr. 72, Pr. 240
Pr. 54,Pr. 55, Pr. 56, Pr. 158, Pr. 900, Pr. 901
Pr. 54,Pr. 55, Pr. 56, Pr. 900
Pr. 37, Pr. 52, Pr. 53
Pr. 171
Pr. 76
Pr. 77
Pr. 78
Pr. 160, Pr. 173 to Pr. 176
Pr. 199
Pr. 261 to Pr. 266
Pr. 180 to Pr. 186
Pr. 190 to Pr. 195
Pr. 244
Pr. 9
Pr. 65, Pr. 67, Pr. 68, Pr. 69
Pr. 990
Pr. 75
Pr. 251
Pr. 503, Pr. 504
71
Get other manuals https://www.bkmanuals.com
PARAMETERS
Parameter Numbers
Parameter numbers which must be set
4