4.10.1 List of parameters classified by purpose of use

Set the parameters according to the operating conditions. The following list indicates purpose of use and
corresponding parameters.
Adjust the output torque of
the motor (current)
Limit the output frequency
Set V/F pattern
Frequency setting with
terminals (contact input)
Acceleration/deceleration
time/pattern adjustment
Selection and protection of a
motor
Motor brake and stop
operation
Function assignment of
external terminal and control
Monitor display and monitor
output signal
Detection of output frequency
and current
Purpose of Use
Manual torque boost
Simple magnetic flux vector control
Slip compensation
Stall prevention operation
Multiple rating setting
Maximum/minimum frequency
Avoid mechanical resonance points (frequency jump)
Base frequency, voltage
V/F pattern matching applications
Adjustable 5 points V/F
Multi-speed setting operation
Jog operation
Input compensation of multi-speed and remote setting
Remote setting function
Acceleration/deceleration time setting
Starting frequency
Acceleration/deceleration pattern and backlash measures
Regeneration avoidance functions at deceleration
Motor protection from overheat (electronic thermal relay
function)
Use the constant torque motor (applied motor)
DC injection brake
Selection of regeneration unit
Selection of motor stopping method
Decelerate the motor to a stop at instantaneous power failure
Function assignment of input terminal
Start signal selection
Logic selection of output stop signal (MRS)
Selection of action conditions of the second function signal (RT)
Terminal assignment of output terminal
Detection of output frequency (SU, FU, FU2 signal)
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Remote output function (REM signal)
Speed display and speed setting
Change of DU/PU monitor descriptions
Cumulative monitor clear
Change of the monitor output from terminal CA and AM
Adjustment of terminal CA and AM (calibration)
Energy saving monitor
Detection of output frequency (SU, FU, FU2 signal)
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Parameter list
Parameter Number
Pr. 0, Pr. 46
Pr. 80, Pr. 90
Pr. 245 to Pr. 247
Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr.
148, Pr. 149, Pr. 154, Pr. 156, Pr. 157
Pr. 570
Pr. 1, Pr. 2, Pr. 18
Pr. 31 to Pr. 36
Pr. 3, Pr. 19, Pr. 47
Pr. 14
Pr. 71, Pr. 100 to Pr. 109
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 15, Pr. 16
Pr. 28
Pr. 59
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45
Pr. 13, Pr. 571
Pr. 29, Pr. 140 to Pr. 143
Pr. 882 to Pr. 886
Pr. 9, Pr. 51
Pr. 71
Pr. 10 to Pr. 12
Pr. 30, Pr. 70
Pr. 250
Pr. 261 to Pr. 266
Pr. 178 to Pr. 189
Pr. 250
Pr. 17
Pr. 155
Pr. 190 to Pr. 196
Pr. 41 to Pr. 43, Pr. 50
Pr. 150 to Pr. 153, Pr. 166,
Pr. 167
Pr. 495 to Pr. 497
Pr. 37, Pr. 144
Pr. 52, Pr. 170, Pr. 171, Pr. 563, Pr.
564, Pr. 891
Pr. 54 to Pr. 56, Pr. 158, Pr. 867, Pr. 869
C0 (Pr. 900), C1 (Pr. 901)
Pr. 891 to Pr. 899
Pr. 41 to Pr. 43, Pr. 50
Pr. 150 to Pr. 153, Pr. 166,
Pr. 167