Func-
Parameter
tion
Number
Commercial power supply-inverter
135
switch-over sequence output
terminal selection
136
MC switch-over interlock time
137
Start waiting time
Commercial power supply-inverter
138
switch-over selection at alarm
occurrence
Automatic inverter-commercial
139
power supply switch-over
frequency
Backlash acceleration stopping
140
frequency (Note 7)
Backlash acceleration stopping
141
time (Note 7)
Backlash deceleration stopping
142
frequency (Note 7)
Backlash deceleration stopping
143
time (Note 7)
144
Speed setting switchover
145
PU display language selection
Stall prevention operation level at
148
0V input
Stall prevention operation level at
149
10V input
150
Output current detection level
151
Output current detection period
152
Zero current detection level
153
Zero current detection period
Voltage reduction selection during
154
stall prevention operation
155
RT signal activated condition
156
Stall prevention operation selection
157
OL signal waiting time
158
AM terminal function selection
160
User group read selection
Automatic restart after
162
instantaneous power failure
selection
163
First cushion time for restart
164
First cushion voltage for restart
Restart stall prevention operation
165
level
168
Maker setting Parameters. Do not make setting.
169
170
Watt-hour meter clear
171
Actual operation hour meter clear
173
User group 1 registration
174
User group 1 deletion
175
User group 2 registration
176
User group 2 deletion
Name
Setting Range
0, 1
0 to 100.0 s
0 to 100.0 s
0, 1
0 to 60.00Hz, 9999
0 to 400Hz
0 to 360 s
0 to 400Hz
0 to 360 s
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
0 to 200%
0 to 200%
0 to 200%
0 to 10 s
0 to 200.0%
0 to 1 s
0, 1
0, 10
0 to 31, 100, 101
0 to 25 s, 9999
1 to 3, 5 to 14,
17, 18, 21
0, 1, 10, 11
0, 1
0 to 20 s
0 to 100%
0 to 200%
0 to 999
0 to 999, 9999
0 to 999
0 to 999, 9999
67
Get other manuals https://www.bkmanuals.com
Minimum
Setting
Factory Setting
Increments
1
0.1 s
0.1 s
1
0.01Hz
0.01Hz
0.1 s
0.01Hz
0.1 s
1
0.1%
0.1%
0.1%
0.1 s
0.1%
0.01 s
1
1
1
0.1 s
1
1
1
0.1 s
0.1%
0.1%

0

0
1
1
1
1
PARAMETERS
Refer
Customer
To
setting
Page:
0
148
1.0 s
148
0.5 s
148
0
148
9999
148
1.00Hz
86
0.5 s
86
1.00Hz
86
0.5 s
86
4
89
150%
84
200%
84
150%
153
0
153
5.0%
154
0.5 s
154
1
84
0
155
0
155
0
157
1
92
0
158
0
96
0 s
96
0%
96
150%
96
0
159
0
159
0
158
0
158
0
158
0
158
4