4.2.61 High-speed frequency control (Pr. 271 to Pr. 274)

Pr. 271 "high-speed setting maximum current"
Pr. 272 "mid-speed setting minimum current"
Pr. 273 "current averaging range"
Pr. 274 "current averaging filter constant"
Used to set the current, averaging range, etc. required when "2" or "3" is set in Pr. 270 to select load torque
high-speed frequency control.
Parameter
Factory
Number
Setting
271
50%
272
100%
273
9999
274
16
(Note) When load torque high speed
frequency control is selected,
automatic restart after instantaneous
power failure function is invalid.
<Wiring example>
• Sink logic
• Pr. 186 = 19
Note: The input signal terminal used depends on the Pr. 180 to Pr. 186 settings.
Setting Range
<Without high-speed frequency control>
0 to 200%
0 to 200%
0 to 400Hz, 9999
1 to 4000
NFB
Power supply
Start signal
Load torque high-speed
frequency function selection
Get other manuals https://www.bkmanuals.com
R elated param eters
Pr. 4 "multi-seed setting (high speed)"
Pr. 5 "multi-seed setting (middle speed)"
Pr. 6 "multi-seed setting (low speed)"
Pr. 59 "remote setting function selection"
Pr. 180 to Pr. 186
(input terminal function selection)
Pr. 270 "stop-on-contact/load torque
high-speed control selection"
Whether there is a load or
not, the lift is moved vertically
at the same speed.
MC
Mechanical
U
R
V
S
W
T
STF
CS (Note)
SD
174
PARAMETERS
<With high-speed frequency control>
Light
Faster
The lift with a light load or without
a load is moved faster than the
lift with a load.
(The output frequency is increased.)
brake
Motor