7.1 Standard Specifications; Model Specifications - Mitsubishi Electric FR-A520-0.4K Instruction Manual

Hide thumbs Also See for FR-A520-0.4K:
Table of Contents

Advertisement

7.1 Standard Specifications

7.1.1

Model specifications

! ! ! ! 200V class
Type FR-A520-""K
0.4
Applicable
motor capacity
kW
0.4
(Note 1)
Rated capacity
1.1
(kVA) (Note 2)
Rated
3
current (A)
Overload current
capacity (Note 3)
Voltage (Note 4)
Regen-
Maximum
erative
value
15% torque/3%ED
braking
/Permissi-
torque
ble duty
Rated input AC
voltage, frequency
Permissible AC
voltage fluctuation
Permissible
frequency fluctuation
Power supply system
1.5
capacity (kVA) (Note 6)
Protective structure
(JEM 1030)
Cooling system
Self-cooling
Approx. weight (kg),with
2.0
DU
Note: 1. The applicable motor capacity indicated is the maximum capacity applicable for use of the
Mitsubishi 4-pole standard motor.
2. The rated output capacity indicated assumes that the output voltage is 220V for 200V class and
440V for 400V class.
3. The % value of the the overload capacity indicates the ratio of the overload current to the
inverter's rated output current. For repeated duty, allow time for the inverter and motor to return to
or below the temperatures under 100% load.
4. The maximum output voltage does not exceed the power supply voltage. You can set the
maximum output voltage to any value below the power supply voltage. However, the pulse
voltage value of the inverter output side voltage remains unchanged at about
supply.
5. Short duration rating 5s
6. The power supply capacity varies with the value of the power supply side inverter impedance
(including those of the input reactor and cables).
7. The open type (IP00) is used when the plug-in option is fitted after removal of the option wiring
port cover.
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
1.9
3.1
4.2
6.7
5
8
11
17.5
150% 60s, 200% 0.5s (inverse-time characteristics)
Three-phase, 200 to 220V 50Hz, 200 to 240V 60Hz
100%
torque/3%ED
torque/2%ED
(Note 5)
(Note 5)
Three-phase, 200V to 220V 50Hz, 200 to 240V 60Hz
170 to 242V 50Hz, 170 to 264V 60Hz
2.5
4.5
5.5
9
Enclosed type (IP20) (Note 7)
2.5
3.5
3.5
3.5
220
Get other manuals https://www.bkmanuals.com
5.5
7.5
11
15
18.5
5.5
7.5
11
15
18.5
9.2
12.6
17.6
23.3
29
24
33
46
61
76
100%
20% torque/continuous
(Note 5)
±5%
12
17
20
28
34
Forced air cooling
6.0
6.0
8.0
13.0
13.0
SPECIFICATIONS
22
30
37
45
55
22
30
37
45
55
34
44
55
67
82
90
115
145
175
215
Three-phase, 200 to
220V 50Hz,
200 to 230V 60Hz
Three-phase, 200 to
220V 50Hz,
200 to 230V 60Hz
170 to 242V 50Hz, 170 to
253V 60Hz
41
52
66
80
100
Open type (IP00)
13.0
30.0
40.0
40.0
55.0
that of the power
2

Advertisement

Table of Contents
loading