5.1.15 Expert menu (TIG)
The Expert menu has adjustable parameters stored that don't require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
Display
099-00T500-EW501
30.1.2023
2s
Setting/selection
Slope time (main current to secondary current)
Slope time (secondary current to main current)
Parameter activArc > see 5.1.9 chapter
Setting the intensity
Pulse shape
------ hard rectangular current curve and high arc force that however generates a lou-
der arc noise (factory setting)
------ rectangular current curve with rounded edges and low noise. For universal
welding tasks
------ heavily rounded current curve, lower arc force and low arc noise
Functional characteristics
DC
AcS=nEt
AcS=nEt
Figure 5-36
TIG welding
2s
51