Functional characteristics
Machine configuration menu
Display
66
Setting/selection
Start JOB
Set first retrievable JOB (setting: 1 to 100, factory setting 1).
Remote control menu
Responsiveness > see 5.1.14.2 chapter
------- Linear responsiveness
------- Logarithmic responsiveness (factory setting)
Start program of foot-operated remote control > see 5.1.14.3 chapter
------- Function enabled (factory setting).
------- Function disabled.
End program of foot-operated remote control > see 5.1.14.4 chapter
------- Function enabled.
------- Function disabled (factory setting).
Start / stop operation > see 5.1.14.5 chapter
------- Function enabled.
------- Function disabled (factory setting).
Welding current polarity switching
------- polarity switching at the RT PWS 1 19POL remote control (ex works)
------- polarity switching at the welding machine control
Torch cooling menu
Torch cooling mode
------- Automatic operation (ex works)
------- Permanently enabled
------- Permanently disabled
Welding torch cooling, post-flow time
Setting 1–60 min. (ex works 5 min.)
Temperature error limit
Setting 50 - 80°C / 122 - 176°F (factory setting 70°C / 158°F)
Flow monitoring
------- Function disabled
------- Function enabled (factory setting)
Flow error limit
Setting 0.5 l - 2.0 l / 0.13 gal - 0.53 gal (factory setting 0.6 l / 0.16 gal)
Reset Cool
------- Function enabled
------- Function disabled (factory setting)
Service menu
Any changes to the service menu should be agreed with the authorised service person-
nel.
Reset (resetting to factory settings)
------- Switched off (factory setting)
------- Reset of values in the machine configuration menu
------- Complete reset of all values and settings
------- Reset of operating time
------- Reset of arc time
------- Reset of operating time and arc time
Resetting is performed when exiting the menu (
Software version query
System bus ID and version number are separated by a dot.
Example: 07.0040 = 07 (system bus ID) 0.0.4.0 (version number)