Functional characteristics
TIG welding

5.1.14.4 End program

The end program "
menu > see 5.10 chapter.
Enabled end program
The activation of the end program is suitable for adjusting the working area (lower limit increased) for the
end-crater fill. The down-slope time "
adjusted individually. The end program starts with the down-slope time on ending the control by using
foot-operated remote control (release).
Disabled end program
When the end program is deactivated after releasing the foot-operated remote control, the welding pro-
cess ends according to the set lower limit (factory setting).

5.1.14.5 Start/stop operation

Start/stop operation "
menu > see 5.10 chapter.
Enabled start/stop operation
The foot-operated remote control is no longer used to specify the welding current, but rather starts or
ends the welding process (see torch trigger). As in normal operation, the welding current is specified u-
sing the power source control or the welding torch with the up/down function. All operating modes (non-
latched, latched, etc.) can be selected.
Disabled start/stop operation
The welding current is specified using the foot-operated remote control. In this setting, only the non-
latched operating mode is possible. (factory setting).
50
" can be enabled or disabled in the machine configuration
", the end current "
" can be enabled or disabled in the machine configuration
" and the end current time "