1.4 Terminal Units (AC500 Standard)
1.4.1 TU507-ETH and TU508-ETH for Ethernet Communication Interface Modules
●
TU507-ETH, Ethernet terminal unit, 24 VDC, screw terminals
●
TU508-ETH, Ethernet terminal unit, 24 VDC, spring terminals
●
TU508-ETH-XC, Ethernet terminal unit, 24 VDC, spring terminals, XC version
2019/04/17
Terminal Units (AC500 Standard) > TU507-ETH and TU508-ETH for Ethernet Communication Interface Modules
Hot swap
Preconditions for hot swapping I/O modules:
–
Hot-swappable terminal units have the appendix TU5xx-H.
–
I/O modules as of index F0.
–
Communication interface modules CI5xx as of index F0.
Hot swapping is only allowed for I/O modules.
Processor modules and communication interface modules must not be removed
or inserted during operation.
Hot Swap
Further Information about Hot Swap for V2 Products see System Technology.
Further Information about Hot Swap for V3 Products see System Technology.
3ADR010121, 13, en_US
Device Specifications
145