Kontrollen Und Momentanwerte (Controls And Instantaneous Values); Alarme (Alarms); Momentanwerte (Instantaneous Values) - janitza Procont-LMC User Manual And Technical Data

Load management controller
Table of Contents

Advertisement

www.janitza.de
21.2
Kontrollen und Momentanwerte (Con-
trols and instantaneous values)
10:00:00 MI 10.05.2022
10:00:00 MI 10.05.2022
HZ: 0.00 kW
HZ: 0.00 kW
10.0m
10.0m
HT/Wint.
HT/Wint.
Abg.LG: 0
Abg.LG: 0
<Hauptzähleralarm>
<Hauptzähleralarm>
Time and date, current power, period time, current
tariff, switched-off load groups
Use the cursor keys > and < to switch between the
displays.
21.2.1

Alarme (Alarms)

Anstehende Alarme: 1
Anstehende Alarme: 1
Hauptzähleralarm
Hauptzähleralarm
3
3
The pending alarms (Anstehende Alarme) are dis-
played here. Meaning of the number on the right.
1: Alarm was active, but has not been acknowl-
edged
2: Alarm is active, has been acknowledged
3: Alarm is active and has not yet been acknowl-
edged
21.2.2

Momentanwerte (Instantaneous values)

Sollwert:
Sollwert:
Sollwert:
Sollwert:
25.00kW
25.00kW
25.00kW
25.00kW
2
2
2
2
Max-Wert: 10.00kW
Max-Wert: 10.00kW
Mom.Lstg: 0.00kW
Mom.Lstg: 0.00kW
Trend:
Trend:
0.00kW
0.00kW
Instantaneous value view 1
Sollwert:
Sollwert:
25.00kW
25.00kW
2
2
Max-Wert: 10.00kW
Max-Wert: 10.00kW
Mom.Lstg: 0.00kW
Mom.Lstg: 0.00kW
Trend:
Trend:
0.00kW
0.00kW
Sollwert (Set point):
· Current setpoint of the power in kW
· Max-Wert (Max value): A maximum value limit
can be entered to protect feeder fuses or feeder
cables. If the instantaneous power exceeds the
preset maximum power, the loads are switched
off, just as when the setpoint is exceeded.
(Always select max. value to be higher than the
setpoint!).
Mom. Lstg: Instantaneous power determined
Trendwert (Trend value): The trend value average
shows the
rent period, calculated for the period duration (e.g.
15 min).
Instantaneous value view 2
Kr: The correction value (Kr) prevents the setpoint
from being exceeded.
Tr: The trend value (Tr) shows the average con-
sumption of the current period, extrapolated to the
period duration (e.g.: 15 minutes).
Mx: The measured maximum power of the current
period
mM: Mean maximum is the averaged power of the
current period
P: Instantaneous power
Kr: 8.94
Kr: 8.94
Tr:
Tr:
0.00
0.00
Mx: 0.00
Mx: 0.00
mM: 0.00
mM: 0.00
P:
P:
0.00
0.00
Re: 36.59
Re: 36.59
Re: The power that may be consumed on average
Pm: 0.00
Pm: 0.00
Ku:
Ku:
0.00
0.00
in the remaining time of the current period without
exceeding the set setpoint.
So: 25.00 Zt:
So: 25.00 Zt:
5.7
5.7
Pm: Averaged actual value of power
Tr: 0.00
Tr: 0.00
Ku:
Ku:
0.00
0.00
KA: 11.23
KA: 11.23
Ku: The cumulative power shows the work that
KE: 11.48
KE: 11.48
has been consumed in the current period, calculat-
ed over the period duration.
Procont
-LMC | Procont
®
average consumption of the cur-
Kr: 8.94
Kr: 8.94
Tr:
Tr:
0.00
0.00
Mx: 0.00
Mx: 0.00
mM: 0.00
mM: 0.00
P:
P:
0.00
0.00
Re: 36.59
Re: 36.59
Pm: 0.00
Pm: 0.00
Ku:
Ku:
0.00
0.00
TE
-LMC-LI
®
49