Function Mapping - tams elektronik FD-R Basic.3 Manual

Funktions decoder
Table of Contents

Advertisement

FD-R Basic.3

8.2. Function mapping

The assignment of the actions controlled by the decoder
switching the function outputs on and off
(de)activation of the special function "Shunting mode / Shunting
light" (SM)
to the functions is carried out according to RailCommunity standard
RCN-227. Note: Function mapping is not possible with pure Motorola
central units.
To get access to the corresponding memory area (the so-called
"page"), the values for "Function mapping" must be set in CV 31 and 32
(= default values).
Name
Index for
higher pages
According to RCN-227, eight configuration variables (CVs) are assigned
to each function (F0 to F28) (four each for forward ("f") and reverse
("r"). Six of them are used for the function decoder FD-R Basic.3 (3 for
forward and 3 for reverse):
2 CVs for the outputs (F0f, F0r, AUX1 and AUX2): Here you set
which outputs are switched with the function.
1 CV for the special function "Shunting mode / Shunting light" (SM):
Here you set which function is used to activate the shunting mode.
Switch-off function: Here you can define a function with which you
can switch off the actions assigned to the function when switching
on. The value "255" determines that the actions are switched off
with no function.
No.
Input values
(Default)
31
0 ... 255 (0)
32
0 ... 255 (42) Function mapping
Remarks and tips
Function mapping
English
0
42
Page 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

42-0118042-01181