Art.-Nr. 41-01330 / 41-01331 / 41-01332
Art.-Nr. 41-02330 / 41-02331
Décodeur pour locomotive
avec moteur continu / alternatif
gelijk-/ wisselstroommotoren
LD-G-33
LD-W-33
Locomotive Decoder
for DC / AC engines
Locdecoder voor
DCC
n
n
n
n
n
n
n
n
n
n
n
n
n
n
MM
n
n
Manual
Mode d´emploi
Handleiding

Advertisement

Table of Contents
loading

Summary of Contents for tams elektronik LD-G-33

  • Page 1 LD-G-33 Art.-Nr. 41-01330 / 41-01331 / 41-01332 LD-W-33 Art.-Nr. 41-02330 / 41-02331 Locomotive Decoder for DC / AC engines Manual Décodeur pour locomotive Mode d´emploi avec moteur continu / alternatif Handleiding Locdecoder voor gelijk-/ wisselstroommotoren...
  • Page 2 © 06/2008 Tams Elektronik GmbH All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, without prior permission in writing from Tams Elektronik GmbH. Subject to technical modification.
  • Page 3: Table Of Contents

    5. Technical specifications 6. Mounting the locomotive decoder 7. Programming the locomotive decoder 8. Configuration variables and the registers of the LD-G-33 and the LD-W-33 9. Operation 10. Check list for trouble shooting 11. Manufacturer's note, CE and Warranty Connections (Fig. 1, 2 and 3) Connections (Fig.
  • Page 4: Getting Started

    Intended use The locomotive decoder is designed for mounting in a model train with DC motor (LD-G-33) resp. AC motor (LD-W-33). It evaluates the Motorola or DCC format data sent by the digital central unit to its address and controls the locomotive´s motor and additional functions.
  • Page 5: Safety Instructions

    LD-G-33 / LD-W-33 English Checking the package contents Check the contents of the package for completeness after unpacking: § one decoder, with or without soldered connecting wires resp. soldered NEM 652 interface connector, depending on the version, § one electrolytic capacitor 100 µF / 35 V, §...
  • Page 6 English LD-G-33 / LD-W-33 § connecting the circuit to another voltage than specified, § impermissibly high humidity, § condensation build up can cause serious injury due to electrical shock. Take the following precautions to prevent this danger: § Never perform wiring on a powered decoder.
  • Page 7: Safe And Correct Soldering

    LD-G-33 / LD-W-33 English Dangerous environments A working area that is too small or cramped is unsuitable and can cause accidents, fires and injury. Prevent this by working in a clean, dry room with enough freedom of movement. Other dangers Children can cause any of the accidents mentioned above because they are inattentive and not responsible enough.
  • Page 8: Operation Overview

    English LD-G-33 / LD-W-33 § Apply the soldering tip to the soldering spot in such a way that the wire and the soldering eye are heated at the same time. Simultaneously add solder (not too much). As soon as the solder becomes liquid take it away.
  • Page 9 The automatic recognition of the analogue mode can be switched off. The load control of the LD-G-33 is is also active in analogue mode. The set maximum speeds also limits in analogue mode the maximum speed of the locomotive.
  • Page 10 LD-G-33 / LD-W-33 Load control (only with the LD-G-33) The locomotive decoder LD-G-33 for DC motors has a load control, the decoder LD-W-33 for AC motors does not have this function. The load control influences the motor voltage to keep the locomotive at constant velocity, independent of additional loads (e.g.
  • Page 11 Emergency stop At a change of direction an emergeny stop is carried out automatically. Slider commutation The LD-G-33 or the LD-W-33 has a function output to be programmed so that it switches a relay for slider commutation. Function outputs The decoder has six function outputs with a maximum current of 500 mA each, which are available to connect optional accessories (e.g.
  • Page 12 English LD-G-33 / LD-W-33 SUSI interface A SUSI module can be connected to the LD-G-33 or the LD-W-33 and programmed via the decoder. It is not possible to read the SUSI module´s data via the decoder. The locomotive decoder transmits the function status and the speed level set at the central unit, to the SUSI module.
  • Page 13: Technical Specifications

    (so-called detectors). The decoders must be designed to send the RailCom messages. The LD-G-33 / LD-W-33 sends (continuously) the (basic, extended or consist) address to the detectors (so-called RailCom broadcast datagramm) and transfers a CV message after a DCC CV read-out command.
  • Page 14: Mounting The Locomotive Decoder

    English LD-G-33 / LD-W-33 6. Mounting the locomotive decoder Before mounting the decoder check if the maximum locomotive motor´s current on-load is below the maximum permissible value of 1.000 mA. If it is above 1.000 mA the decoder is not suitable for mounting in this locomotive.
  • Page 15 LD-G-33 / LD-W-33 English Next solder the connections of the field coil to the points X3 and X4 and the connection of the motor sheild to the point RL. Should the locomotive´s direction of motion in analogue mode not match the direction of motion set at the speed control you have to swap the connections to the points X3 and X4.
  • Page 16 English LD-G-33 / LD-W-33 Tip: Before starting to program the locomotive decoder you should connect the motor to the decoder. Otherwise there is no confirmation signal from the (DCC-) central unit. Should you intend to program the decoder with a Motorola central unit you should always connect the lighting to the outputs AUX1 and AUX2.
  • Page 17 LD-G-33 / LD-W-33 English You can connect several LEDs in parallel to each output. In this case every LED must have a series resistor of its own. If you connect several LEDs to one output in series, only one series resistor is needed.
  • Page 18: Programming The Locomotive Decoder

    English LD-G-33 / LD-W-33 7. Programming the locomotive decoder In DCC format it is possible to program register or configuration variables (CVs), main track programming can be used as well. In Motorola format the settings are saved in registers. Programming with DCC central units You can programm the configuration variables (CV) of the decoder from the digital central unit.
  • Page 19 LD-G-33 / LD-W-33 English current address). Manufacturers setting is "3". Set all functions (function, f1 to f4) to "off". Push the "stop" button at the central unit. Next, operate the direction switch and hold it in that position while briefly pushing the "go" button.
  • Page 20: Configuration Variables And The Registers

    LD-G-33 and the LD-W-33 The following list shows all configuration variables (for the DCC format) and registers (for the Motorola format), that can be set for the LD-G-33 and the LD-W-33. In the list you will find in the column "CV-no." the numbers of the configuration values for programming in DCC format and in the column "Reg.-no."...
  • Page 21 LD-G-33 / LD-W-33 English * For some configuration variables, the input values have to be calculated by adding the numerical values assigned to the desired parameters. Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Basic address 1 ...
  • Page 22 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Maximum 0 ... 255 = The voltage to be output to voltage the motor at the highest speed level. The value "2" corresponds to 0,8 %, the "255" to 100 % of the max.
  • Page 23 LD-G-33 / LD-W-33 English Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Motor 0, 1 Numerical value* frequency 31,5 kHz for LD-G-33 17 kHz Tip: In case that the locomotive´s driving characteristics are not satisfactory with the standard setting of 31,5 kHz, the motor frequency of 17 kHz should be chosen.
  • Page 24 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Extended 192 ... 255 Only for DCC format. Most address (192) central units permit entering extended addresses directly. 0 ... 255 The CVs # 17, 18 and 29 are...
  • Page 25 LD-G-33 / LD-W-33 English Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Configuration 0 ... 64 Numerical value* data 1 (14) Direction "Standard" Reverse direction 14 speed levels 28 or 128 speed levels Analoge recognition off...
  • Page 26 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Assignment of the function keys to the Numerical value* outputs Assigned output: F0 forward on 33 0 ... 63 (1) AUX1 F0 backward on 34 0 ...
  • Page 27 KP (40) The parameter KP defines the basic speed (for LD-G-33 only). A too small value à locomotive too slow. A too high value à heavy shaking of the locomotive. Parameter of 0 ... 255 = Integral component of the load control.
  • Page 28 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Effects of the outputs Numerical value* AUX1 0 ... 63 (0) Independent of direction AUX2 0 ... 63 (0) AUX off at forward motion AUX3 0 ...
  • Page 29 LD-G-33 / LD-W-33 English Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Dimming of the outputs: = Reduction of the voltage applied to the output. The AUX1 / AUX2 1...255 (255) value "1" corresponds to the AUX3 / AUX4 1...255 (255)
  • Page 30 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Flashing 112 38 10 ... 255 Settings common for all frequency of (200) lighting. the lighting 10 à lowest frequency 255 à highest frequency Examples for the flashin frequency: CV#112 = 10 à...
  • Page 31 LD-G-33 / LD-W-33 English Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Dimming 116 43 0 ... 63 Determines which outputs depending on have to be dimmed from the the speed level speed level defined in CV#113.
  • Page 32 English LD-G-33 / LD-W-33 Name of CVs / Reg. Input value Remarks and Tips Registers (Default) Switching off 121 57 0...255 Determines the functions (F1 function F0 at to F8) to switch off the speed level 0 function F0 at speed level 0.
  • Page 33: Operation

    Optimising the CV-settings Above all, the driving characteristics can be influenced by setting the CV#2 (starting voltage) and CV#5 (Maximum voltage) and for the LD-G-33, in addition, the CV#50 to #52 (parameters of the load control). As a rule, the following settings lead to good driving characteristics :...
  • Page 34: Check List For Trouble Shooting

    English LD-G-33 / LD-W-33 10. Check list for trouble shooting § Parts are getting very hot and/or start to smoke. Disconnect the system from the mains immediately! Possible cause: one or more connections are soldered incorrectly. à Check the connections.
  • Page 35: Manufacturer's Note, Ce And Warranty

    LD-G-33 / LD-W-33 English speed levels, but the decoder to the mode 14 speed levels. à Change the speed mode at the central and / or at the decoder. § The CV values cannot be read out. Possible cause: RailCom is switched off.
  • Page 36 English LD-G-33 / LD-W-33 specifications of the circuit when assembled and connected according to the manual. Other claims are excluded. By law, we are not responsible for damages or secondary damages in connection with this product. We retain the right to repair, make improvements, supply spare parts or return the purchase price.
  • Page 37 LD-G-33 / LD-W-33 LD-G-33 / LD-W-33 Fig. 1: Anschluss – Connections – Connexion - Aansluiten LD-G-33 Fig. 3: Anschluss der Ausgänge an Fahrzeugmasse Connection of the outputs to vehicle ground Raccordement des sorties via la masse du vehicule Verbining van de uitgangen met de voortuigmassa AUX1 bis Ausgänge (max.
  • Page 38 LD-G-33 / LD-W-33 LD-G-33 / LD-W-33 Fig. 4: Fig. 5: Schaltplan - Circuit diagram - Schéma de principe - Schakelschema Anschluss eines SUSI-Moduls und eines Stützelkos Connecting a SUSI-module and a smoothing capacitor Connexion d´un module SUSI et d´un condensateur...
  • Page 39 Actuele informatie en tips: http://www.tams-online.de Garantie und Service: Warranty and service: Garantie et service: Garantie en service: Tams Elektronik GmbH Rupsteinstraße 10 D-30625 Hannover fon: +49 (0)511 / 55 60 60 fax: +49 (0)511 / 55 61 61 e-mail: info@tams-online.de...