Saving Configuration - Viavi FCOMP/-PRO T-BERD/MTS-2000V2 User Manual

Table of Contents

Advertisement

Fiber Number
Change Fiber Nbr Select Change Fiber Nbr and select
Increment
Decrement
User defined
Note: to decrement the number, enter the sign «-» before the number. Example: -1.
Min: -999 / Max: 999 / Auto: 0
No
Cable Id

Saving configuration

Once the File and Measurement parameters are configured, it can be saved in a config-
uration file.
This configuration file can then be recalled for future acquisition in Loopback mode.
NOTE
The configuration from Loopback Setup page can be saved exclusively if the
ExpertOTDR function is selected at the same time on the Home page.
To save parameters in a configuration file:
1
In the Setup menu, press menu key
An edition keyboard displays
2
Enter a name for the configuration file.
Select the Fiber number parameter and click on left or right arrow
to modify the Number
the fiber number is automatically incremented at each new
file-save.
the fiber number is automatically decremented at each
new file-save
Use Edit Number softkey to enter the increment/decre-
ment value for fiber number.
the Fiber number must not automatically modified.
Select the Cable Id parameter and click on the right arrow to
display the edition keypad and enter/modify the cable identifier.
User Manual
Configuring the Loopback Test
700MAN203 Rev. 007
Chapter 5 Loopback OTDR
.
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcomp/-pro t-berd/mts-4000v2

Table of Contents