7-34 Troubleshooting
Event ID:
Started maintenance operation without suspending (or stopping) HAS Fault
Tolerance service may be the reason for these logs to be recoded.
→ The following event logs may be recorded during the system operation, but there
is no problem in continue operating the system. However, there might be a
problem in OS or software environment if logs are recorded repeatedly. Contact
your maintenance service company.
Source:
Type:
Event ID:
These logs report captured information when the program exception occur within
HAS Fault Tolerance service. The program exception occurs for various reasons, but
HAS Fault Tolerance service has allowance function that can handle the problem. It is
also set to self-recover even when exceeding the allowance range.
HasCtrl-related logs are recorded in the system event log:
→ The following event logs may be recorded during the system operation. This log
shows that CPU module is not in a dual mode. There is no problem to the system
by this warning, since CPU module will be set to a dual mode again.
Source:
Type:
Event ID:
Description: The driver failed the fast re-sync function of the CPU module
Source:
Type:
Event ID:
Description: The error occurred on the CPU module of Module [Module
Source:
Type:
Event ID:
Description: The error occurred on the CPU module of Module [Module
Source:
Type
Event ID:
Description: Synchronization of the CPU module stopped.
209 - 213
HAS Fault Tolerance
Error
300
HasCtrl
Warning
1202
[Module[Module Number]]
[Module Number] "#0" or "#1"
HasCtrl
Warning
3500
Number].
[Module Number] "#0" or "#1"
HasCtrl
Warning
4000
Number].
[Module Number] "#0" or "#1"
HasCtrl
Warning
4310