Idis DR-2516P Operation Manual page 64

Hide thumbs Also See for DR-2516P:
Table of Contents

Advertisement

Part 2 - Configuration
Monitoring Options
Define monitoring times. If self-
diagnosis is not performed on a
System
regular basis, the system will assume
an error.
Bootup,
Define bootup, restart and
Restart,
shutdown actions.
Shutdown
Panic Record
Define panic recording actions.
The system will assume an error if
the system has been scheduled to
record normally but recording does
not take place during scheduled
intervals.
Check
Recording
The system will assume an error if
Check Alarm-
the alarm-in status does not change
In
during the specified monitoring
interval while alarm-in is active.
Generates an event if the disk
Disk Almost
reaches the specified capacity (80%
Full
to 99%).
Generates an event when all disks
Disk Full
reach their maximum capacity.
Generates an event when a disk
Disk Partially
in one of multiple quota groups
Almost Full
reaches the specified capacity (80%
to 99%).
64
Select Schedule On and then
configure the days of the week,
times, and monitoring interval.
Select the
button on the
bottom left of the screen to add
a schedule. Select
icon to
delete the schedule.
Generates an event when a disk
Disk Partially
in one of multiple quota groups
Full
reaches the specified capacity.
Generates an event when the
specified percentage of the disk
Disk Bad
becomes damaged. Set to between
10% and 90% in 10% intervals.
Specify the threshold temperature.
Disk
Once any disk reaches this threshold,
Temperature
the system will issue an alert.
Monitors disks that support
Disk
S.M.A.R.T. and notifies the user if a
S.M.A.R.T.
disk error is detected.
Notifies the user when the fan inside
Fan Error
the system malfunctions.
Storage
Notifies the user if the storage
Disconnected
becomes disconnected while in use.
It will be highlighted when the NVR
Disk Config
reboots after the hard disk drive has
Change
been replaced.
No Storage
It will be highlighted when no hard
Found
disk drive has been connected.
It will be highlighted when login
Consecutive
fails by entering a wrong password
Invalid PW
for consecutive attempts.
It will be highlighted when the
mirroring configuration is broken.
RAID BROKEN
(DR-2504P-A model only)
It will be highlighted when one of
Degrade
the HDDs composing mirroring is in
error. (DR-2504P-A model only)
• For system events, only an e-mail notification of
actions can be selected.
• In order to use the Notify(Callback) feature, the
NVR must be registered to the remote program on
the receiving PC's end.
• For more information on RAID Broken and
Degrade, refer to the Mirror Configuration Error
on page 42.

Advertisement

Table of Contents
loading

Table of Contents