Appendix 7.4 F321 Cable Manufacturing Drawing - Mitsubishi Electric MELDAS C6 Maintenance Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

APPENDIX 7 CABLE MANUFACTURING DRAWINGS

Appendix 7.4 F321 Cable Manufacturing Drawing

Application :
Control unit - manual pulse generator connection
(When connecting two manual pulse generators)
Assembly drawing
Control
1 2
unit side
F321
Note (3)
Connection diagram
Control
unit side
4
1HA
1HB
14
+12V
6
GND
1
2HA
3
2HB
13
+12V
16
11
GND
Manufacturing precautions
(1) The wire material shall be a shielded, 6-pair stranded cable equivalent to UL1061-2464
Standards AWG22 (0.3mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the control unit side over the sheath, and wrap copper foil tape
over it. Connect to the connector case GND plate.
(5) Stamp the name of each signal on the crimp terminal side mark tube and install.
(6) In the catalog specifications, the part 1 connector uses AWG24 (0.2mm
but AWG22 (0.3mm
Appendix 7.4 F321 Cable Manufacturing Drawing
Manual pulse
generator side
3
F321
Case GND plate
2
).
2
) can also be used.
Get other manuals https://www.bkmanuals.com
Option (Compatible connector set)
FCUA-CS000 (Note that only the
control unit connector is compatible)
List of parts used
No.
Part name/type
Connector
1
10120-3000VE
Connector case
2
10320-52F0-008
Wire material
3
UL1061-2464
AWG22 × 6P
Crimp terminal
4
4
V1.25-3
Maximum cable length: 30m
I - 89
Maker
Q'ty
Sumitomo 3M
1
Sumitomo 3M
1
Note (1)
(1)
J. S. T
8
Manual pulse
generator side
1HA
1HB
+12V
GND
2HA
2HB
+12V
GND
2
) or less wire material,

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas c64

Table of Contents