Mitsubishi Electric MELDAS C6 Maintenance Manual page 150

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

[Connector layout diagram]
x 100
x 10
NETWORK
[Explanation of settings]
NETWORK
: Network No. setting switch
Set the network number between 1 and 239 with the three rotary switches. The I/F board group No. is the
number used when setting the local station network number if connecting to MELSECNET/10.
×100 switch
×10 switch
×1 switch
Set within the range of 1 to 239. (Default setting ×100: 0 ×10: 0 ×1: 1)
GROUP
: Group No. setting switch
Set the group number with the rotary switch. The I/F board group No. is the number used when setting the
local stations' group No. if connecting to MELSECNET/10.
Set within the range of 1 to 9. 0 means that no group is designated. (Default setting: 0)
STATION
: Station number setting switch
Set the station numbers between 01 and 64 with the two rotary switches. The I/F board group No. is the
number used when setting the local station number (normal station) if connecting to MELSECNET/10.
×10 switch
×1 switch
Set within the range of 1 to 64. (Default setting ×10: 0 ×1: 1)
MODE
: Mode setting switch
0: Online (automatic parallel-off valid)
1: Online (automatic parallel-off invalid)
2: Offline
3 to 9: Test mode
D: Network No. confirmation
E: Group No. confirmation
F: Station No. confirmation
DIPSW
: Network condition setting
This switch is used to set the MELSECNET/10 operation conditions.
This switch is not used currently. (Always OFF) (Default setting: All OFF)
[Explanation of LEDs]
RUN
: (Green) ON when normal
F.ERR : (Red) ON when main (forward) loop hardware error occurs
R.ERR : (Red) ON when sub (reverse) loop hardware error occurs
F.SD
: (Green) ON during main (forward) loop transmission
F.RD
: (Green) ON during main (forward) loop reception
R.SD
: (Green) ON during sub (reverse) loop transmission
R.RD
: (Green) ON during sub (reveres) loop reception
2. EXPLANATION OF MODULE FUNCTIONS
2.7 HR877/879 Card
x 1
x 10
x 1
GROUP
STATION
DIPSW
: Set the 100th place of the network number.
: Set the 10th place of the network number.
: Set the 1st place of the network number.
: Set the 10th place of the station number.
: Set the 1st place of the station number.
SW1
: PC-PC network
SW2
: Normal station
SW3
: Common parameter
SW4, 5
: Number of stations
SW6, 7
: Size
II - 12
Get other manuals https://www.bkmanuals.com
MODE
ISP
OFF
Remote I/O network
Control station
Default parameter
off, off
on, off
off, on
8 stations 16 stations 32 stations 64 stations
off, off
on, off
off, on
2K point
4K point
6K point
T
OUT
R
T
IN
R
ON
on, on
on, on
8K point
(Default setting: 0)