[Explanation of LEDs]
L1
R1
L2
R2
L3
R3
L4
R4
L5
R5
L6
R6
L7
R7
L8
R8
LED name
ON : Unit is normal
L1 RUN
OFF : Watch dog timer error has occurred.
Indicates the state of communication with
station set in parameters.
ON
L2 ERR.
Flicker : Station with communication error
L3 MST
ON : Set as master station
L4 S MST
ON : Set as standby master station
L5 LOCAL
ON : Set as local station
ON : Communicating with NC CPU
L6 CPU R/W
L7 L RUN
ON : Executing data link (local station)
ON
L8 L ERR.
Flicker : Switch setting was changed while
R1
SW
ON : Switch setting is incorrect
ON : A master station already exists on
R2
M/S
E
R
R3
R
PRM
ON : Error found in parameter details
O
ON : Data link monitor timer functioned
R
R4
TIME
ON : Cable is broken or transmission path
R5
LINE
R6
R7 SD
ON : Sending data
R8 RD
ON : Receiving data
2. EXPLANATION OF MODULE FUNCTIONS
2.8 HR865 Card
Details
: Error in communication with all
stations
round
(FROM/TO)
: Communication error
(local station)
power is ON
same line
(all-station error)
is being affected by noise, etc.
II - 15
Get other manuals https://www.bkmanuals.com
LED display status
Master station
Local station
(Standby master
(Standby master
station)
When
When
When
normal
abnormal
normal
ON
OFF
ON
OFF
ON/flicker
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON/flicker
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
station)
When
abnormal
OFF
ON/flicker
OFF
OFF
ON/flicker
ON
ON
OFF
OFF