Type name
Unit name
Ambient
During operation
temperature
During storage
During operation
Ambient
humidity
During storage
Vibration resistance
Shock resistance
Working atmosphere
Power noise
Power voltage
Instantaneous stop tolerance time
Current consumption
Heating value
Weight
Unit size
Type name
Unit name
Ambient
During operation
temperature
During storage
During operation
Ambient
humidity
During storage
Vibration resistance
Shock resistance
Working atmosphere
Power noise
Power voltage
Instantaneous stop tolerance time
Current consumption
Heating value
Weight
Unit size
(Note 4) Only the amount consumed by the control circuit.
(Note 5) When all points of the machine input/output interface circuit are operating.
3. INSTALLATION
3.1 General Specification
FCUA-LD100/
FCUA-LD10+KB20
Long term, Up to 75% RH (with no dew condensation)
Short term (Within 1 month), Up to 95% RH (with no dew condensation)
Up to 75% RH (with no dew condensation)
Ripple ±5% (P-P)
Follows specifications of 24VDC power supply being used
1600g
FCUA-
DX10
Long term, Up to 75% RH (with no dew condensation)
Short term (Within 1 month), Up to 95% RH (with no dew condensation)
Up to 75% RH (with no dew condensation)
24V, 0.7A
(Note 4)
60W
(Note 5)
470g
I - 7
Get other manuals https://www.bkmanuals.com
FCU6-DUT32
+KB021
Communication terminal
0 to 50°C
–20 to 60°C
2
4.9m/s
or less (during operation)
2
29.4m/s
or less (during operation)
No corrosive gases, dust or oil mist
1kV (P-P)
24VDC±5%
24V, 0.9A
20W
2200g
Refer to Appendix.
FCUA-
FCUA-
DX11
DX12
DX13
Remote I/O unit
0 to 55°C
–20 to 65°C
2
4.9m/s
or less (during operation)
2
29.4m/s
or less (during operation)
No corrosive gases, dust or oil mist
1kV (P-P)
24VDC±5% Ripple ±5% (P-P)
–
24V, 1.5A (Note 4)
110W (Note 5)
570g
590g
Refer to Appendix.
FCUA-CT100/
FCUA-CR10+KB10
0 to 55°C
–20 to 65°C
Single phase 100 to
115VAC
–15%+10%
50/60Hz±5%
24VDC±5%
Ripple ±5% (P-P)
100V, 0.4A
24V, 0.6A
55W
4800g
FCUA-
FCUA-
DX14
24V, 0.7A (Note 4)
60W (Note 5)
550g