The shield wire generally only needs to be grounded
to the connector's case frame. However, the effect
can be improved by directly grounding to the
grounding plate as shown on the right.
Install the grounding plate near each unit. Peel off
part of the cable sheath as shown on the right to
expose the shield sheath. Press that section against
the grounding plate with the clamp fitting. Note that if
the cable is thin, several can be clamped together.
Install the grounding plate directly onto the cabinet or
connect a grounding wire so that sufficient frame
grounding is achieved.
If the AERSBAN-
SET, containing the grounding
plate and clamp fitting, is required, please contact
Mitsubishi.
Outline drawing
Grounding plate
φ
2-
5 hole
Installation hole
Note 1)
6
M4 screw
Note 1) Screw hole for wiring to cabinet's grounding plate
Note 2) The grounding plate thickness is 1.6mm
AERSBAN-DSET
AERSBAN-ESET
17.5
22
35
A
B
C
Enclosed fittings
100
86
30
Two clamp fittings A
70
56
One clamp fitting B
I - 84
Get other manuals https://www.bkmanuals.com
Clamp fitting
(Fitting A,B)
Shield sheath
Clamp section drawing
Clamp fitting
10
MAX L
Clamp fitting A
Clamp fitting B
Cable
Grounding
Plate
L
70
45