Appendix 7.13 Fcua-R055 Cable Manufacturing Drawing - Mitsubishi Electric MELDAS C6 Maintenance Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

APPENDIX 7 CABLE MANUFACTURING DRAWINGS

Appendix 7.13 FCUA-R055 Cable Manufacturing Drawing

Appendix 7.13 FCUA-R055 Cable Manufacturing Drawing
Application :
Control unit - synchronous feed encoder
connection (Right angle type)
Assembly drawing
Control unit side
1 2
Connection diagram
Control unit side
PC2
7
PC2*
17
PB2
8
PB2*
18
PA2
9
PA2*
19
+5V
10
+5V
20
GND
1
GND
11
GND
5
GND
15
Manufacturing precautions
(1) The wire material shall be a shielded, 12-pair stranded cable equivalent to UL1061-2464
Standards AWG22 (0.3mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the control unit side over the sheath, and wrap copper foil tape
over it. Connect to the connector case GND plate.
(5) For the batch connection treatment and shield treatment wire, use AWG24 (0.2mm
equivalent.
(6) In the catalog specifications, the part 1 connector uses AWG24 (0.2mm
but AWG22 (0.3mm
Synchronous feed
encoder side
4 5
3
R055
R055
Note (3)
Case GND plate
2
).
2
) can also be used.
I - 98
Get other manuals https://www.bkmanuals.com
Option (Compatible connector set)
FCUA-CS054
List of parts used
No.
Part name/type
Connector
1
10120-3000VE
Connector case
2
10320-52F0-008
Wire material
3
UL1061-2464
AWG22 × 12P
Right angle plug
4
MS3108B20-29S
Cable clamp
5
MS3057-12A
Maximum cable length: 30m
2
) or less wire material,
Maker
Q'ty
Sumitomo 3M
1
Sumitomo 3M
1
Note (1)
(1)
ITT Cannon
1
ITT Cannon
1
Synchronous feed
encoder side
B
P
C
R
A
N
H
K
2
) or

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas c64

Table of Contents